Kobe CHX30 Range Hood

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Other Documents
CHX30 photo

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

This is the main product document for model CHX30. Series: Brillia Series, CHX30 Series

The file format is pdf, 24 pages, you can download this manual here .

background
KOBE Range Hoods
Brillia Series
CHX30 Series
(290 CFM with CFL Lights)
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
background
IMPORTANT
READ THIS FIRST
READ BEFORE INSTALLATION
1. Carefully check all contents of packages.
2. Thoroughly inspect the unit for any shipping damages, cosmetic
damages or defects.
3. Have a certified contractor/electrician test the unit before installation.
IF THERE IS ANY PROBLEM:
1. DO NOT INSTALL THE UNIT AND KEEP ALL ORIGINAL
PACKAGING MATERIAL.
2. Have your original invoice as proof of purchase and product serial
number ready.
3. Contact your merchant for product replacement due to shipping
damages, cosmetic damages or defects.
4. For all other issues, call 1-877-BUY-KOBE (289-5623), or e-mail to
NO RETURN, NO REFUND, NO EXCHANGE IF:
1. PRODUCT HAS BEEN INSTALLED
2. KNOCK-OUT HOLES HAVE BEEN PUNCTURED
3. MISSING ORIGINAL PACKAGING MATERIAL
AND/OR PARTS
background
[ENGLISH]
- READ AND SAVE THESE INSTRUCTIONS -
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS .................................................................................... 1
COMPONENTS OF PACKAGE.................................................................................................. 3
INSTALLATION .......................................................................................................................... 4
OPERATING INSTRUCTIONS................................................................................................... 9
MAINTENANCE ........................................................................................................................10
SPECIFICATIONS ....................................................................................................................11
MEASUREMENTS & DIAGRAMS .............................................................................................12
PARTS LIST ..............................................................................................................................14
CIRCUIT DIAGRAM ..................................................................................................................16
TROUBLE SHOOTING .............................................................................................................17
WARRANTY .............................................................................................................................18
WARRANTY INFORMATION FORM .........................................................................................20
- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -
ALL W I R I NG MUS T B E DONE B Y A PROFE SSION AL A N D I N
ACCO RD ANCE W I T H NAT IONAL AND LO CAL E LE C TRI CAL CO DES
background
1
IMPORTANT SAFETY INSTRUCTIONS
- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -
WARNING
:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,
OBSERVE THE FOLLOWING:
1) Installation and electrical wiring must be done by qualified professionals and in accordance with all
applicable codes and standards, including fire-rated construction.
2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden
utilities.
3) Ducted fans must be vented to the outside.
a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT SERVICE
PANEL.
b) Clean all grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly,
make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or
garages.
NOTE - This warranty is void without an authorized agent’s receipt or if unit is
damaged due to misuse, poor installation, improper use, mistreatment,
negligence or any other circumstances beyond the control of KOBE
authorized agents. Any repair carried out without the supervision of
KOBE authorized agents will automatically void the warranty.
- KOBE will not be held responsible for any damages to personal property
or real estate or any bodily injuries whether caused directly or indirectly
by the range hood.
WARNING
: TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE
TOP GREASE FIRE:
1. Keep all fan, baffle/spacer/filter/oil tunnel/oil container and grease-laden surfaces clean. Grease
should not be allowed to accumulate on fan, baffle/spacer/filter/oil tunnel/oil container.
2. Always turn hood ON when cooking.
3. Use high settings on cooking range ONLY when necessary.
4. Do not leave cooking range unattended when cooking.
5. Always use cookware and utensils appropriate for the type and amount of food prepared.
6. Use this unit only in the manner intended by the manufacturer.
7. Before servicing, switch power off at service panel and lock service panel (if possible) to prevent
power from switching on accidentally.
8. Clean ventilating fan frequently.
background
2
What to Do In The Event Of a Range Top Grease Fire
SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner.
KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go
out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911.
NEVER PICK UP A BURNING PAN – You May Get Burned.
DO NOT USE WATER, including wet dishcloths or towels – a steam blast will result.
Use an extinguisher ONLY if:
a) You have a Class A, B, C extinguisher and know how to operate it.
b) The fire is small and contained in the area where it started.
c) The fire department has been called.
d) You can fight the fire with your back to an exit.
What to Do If You Smell Gas
-
Extinguish any open flame.
-
Do not try to turn on the lights or any type of appliance.
-
Open all doors and windows to disperse the gas. If you still smell gas, call the Gas Company and
Fire Department right away.
CAUTION
1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.
2) To reduce the risk of fire, use only metal ductwork. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) to prevent back drafting.
3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published
by the National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.
4) Activating any switch on may cause ignition or an explosion.
5) Due to the size and weight of this hood, installation by 2 persons is recommended.
ELECTRICAL SHOCK HAZARD Can result in serious injury or death.
Disconnect appliance from electric power before servicing. If equipped,
the fluorescent light bulb contains small amounts of mercury, which must
be recycled or disposed of according to Local, State, and Federal Codes.
background
3
COMPONENTS OF PACKAGE
(Must keep all material for returns or refunds)
Range Hood Box
{A} KOBE Range Hood – 1
{B} Warranty Registration Card – 1
{C} Instructional Manual – 1
{D} Round Exhaust Plate with damper – 1
{E} Rectangular Exhaust Plate with damper – 1
{F} Light bulb – 1
{G} Parametric Panel – 1
{A} {B}
{C} {D} {E}
{F} {G}
FOR MORE INFORMATION, PLEASE VISIT OUR WEBSITE www.koberangehoods.com OR
CONTACT KOBE RANGE HOODS AT (626) 775-8880.
background
4
INSTALLATION
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING
Calculation before Installation
To calculate installation, please refer to TABLE 1. (All calculation in inches.)
- FOR UNDER THE CABINET -
TABLE 1
A = Height of Floor to Ceiling
B = Height of Floor to Counter Top
(Standard: 36)
C = Preferred Height of Counter Top to Hood
Bottom (Recommended 27” to 30”)
D = Height of Hood
E = Height of the Cabinet
SAFETY WARNING
HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF
REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING.
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY
OCCUR.
background
5
Preparation before Installation
NOTE: TO AVOID DAMAGE TO YOUR HOOD,
PREVENT DEBRIS FROM ENTERING
THE VENT OPENING.
Decide the location of the venting pipe from
the hood to the outside. Refer to Figure 1.
A straight, short venting run will allow the
hood to perform more efficiently.
Try to avoid as many transitions, elbows,
and long run as possible. This may reduce
the performance of the hood.
Temporarily wire the hood to test for proper
operation before installing.
Important: Peel protective film off the hood
(if any).
For installing under the cabinet with
recessed bottom, attach 4-inch wide wood
filler strips (not included) on each side.
Refer to Figure 2.
Using reference on Page 12 and 13 to
measure and create access opening for
electrical wires and exhaust under the
cabinet {refer to Vent Option Installation on
7}. Refer to Figure 3.
Using reference on Page 12 and 13 to
position the mounting screws (not included)
underneath the cabinet. Refer to Figure 4.
Install Lights before mounting hood
To install the light fixture:
-
Insert the light fixture into the socket and
turn it clockwide to secure the light fixture.
Figure 1
Figure 2
Figure 3
Figure 4
background
6
Vent option installation
1. Choose the require vent option.
NOTE: If the hood is to be installed as ductless
application, please do not remove any duct
knockout located at the top or the back of the
hood:
2. For 7” Round vent installation only:
-
Using a flat-head screwdriver to remove the
7” duct knockout. (Refer to Figure 5)
-
Attached the 7” exhaust plate using 8 screws
(provided). Refer to Figure 6.
3. For 3-1/4” x 10” vent installation only:
-
Using a flat-head screwdriver to remove the
top OR the rear 3-1/4” x 10” duct knockout.
(Refer to Figure 7)
-
Attached the 3-1/4” x 10” exhaust plate using
6 screws (provided). Refer to Figure 8 for
Top Vent OR Figure 9 for Rear Vent.
4. For ductless installation only:
-
Remove the recirculating plate located at the
top of the hood, refer to Figure 10.
-
Reinstall the recirculating plate horizontally
as shown in Figure 11.
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
Figure 10
Figure 11
background
7
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS RANGE
HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED
ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL
ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE
PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
5. Connect the electrical wires.
-
Connect three wires (black, white and green)
to house wires and cap with wire connectors.
Connect according to color: black to black,
white to white, and green to green.
Hood Installation
CAUTION: If required to move the cooking
range to install the hood, turn off the power on
an electric range at the main electrical box.
SHUT OFF THE GAS BEFORE MOVING A GAS
RANGE.
6. Align screws with the mounting holes on top of
the range hood, and push toward the wall to
secure the unit in place. Refer to Figure 12 and
Figure 13.
Figure 12
Figure 13
background
8
Final Assembly
7. To install the parametric panel:
-
Align the parametric panel at the back of the
unit. Refer to Figure 14.
-
Push the unit upward, and slide the
parametric panel forward into the notch to
secure the panel. Refer to Figure 15.
-
Flip the parametric panel upward until it
clicks into place. Refer to Figure 16.
CAUTION: MAKE SURE THE PARAMETRIC
PANEL IS SECURE BEFORE RELEASING.
8. Turn power ON in control panel. Check all lights
and fan operation.
9. Make sure to leave this manual for the
homeowner.
Figure 14
Figure 15
Figure 16
background
9
OPERATING INSTRUCTIONS
Note: For best results, turn fan on prior to any preparation or cooking and keep fans running
while cooking. Adjust speed as needed.
To operate the fan function
Press button to choose from speed.
o 1 = Low speed
o 2 = Medium speed
o 3 = High speed
Press “0” to turn fan off.
To operate the light function
Press the Light Control to turn lights on and off.
background
10
MAINTENANCE
SAFETY WARNING
NEVER PUT YOUR HAND INTO AREA HOUSING THE FAN WHILE THE FAN IS OPERATING.
Cleaning Hood Surface
CAUTION
: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS. DO NOT USE
PAPER TOWEL ON STAINLESS STEEL.
For optimal operation, clean range hood and all baffle/spacer/filter/oil tunnel/oil container regularly.
***Regular care will help preserve the appearance of the hood.
1. Use only mild soap or detergent solutions. Dry surfaces using soft cloth.
2. If hood looks splotchy (stainless steel hood), use a stainless steel cleaner to clean the surface of
the hood. Avoid getting cleaning solution onto or into the control panel. Follow directions of the
stainless steel cleaner. Caution: Do not leave on too long as this may cause damage to
hood finish. Use soft towel to wipe off the cleaning solution, gently rub off any stubborn spots.
Use dry soft towel to dry the hood.
3. DO NOT allow deposits to accumulate or remain on the hood.
4. DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface
and cause rusting.
5. DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in
contact with stainless steel for extended periods. Many of these compounds contain chemicals,
which may be harmful. Rinse with water after exposure and wipe dry with a clean lint free cloth.
To Clean Filter
CAUTION: CLEAN FILTER AND PARAMETRIC PANEL PERIODICALLY.
1. Remove parametric panel and aluminum filters.
2. Using a sponge, wash with warm soapy water. Dry completely before returning into place.
NOTE: MAKE SURE THE PARAMETRIC PANEL IS SECURE BEFORE RELEASING.
background
11
SPECIFICATIONS
SERIES
CHX30 Series (290 CFM-CFL)
CONSUMPTION / AMPERE
0.88 Ampere
VOLTAGE
120V 60Hz
NUMBER OF MOTORS
1
DESIGN
20-Gauge Seamless / Satin Finish
with
Glass Parametric panel or Stainless Steel Parametric panel
EXHAUST
Top 7” Round with damper
Top 3-1/4” x 10” Rectangular with damper
Rear 3-1/4” x 10” Rectangular with damper
CONTROLS
Push Button control system
LIGHTS
7-watt CFL light x 2
HOOD DIMENSION
(W x D x H)
30” models – 29-3/4” x 21” x 6”
WEIGHT (lbs)
Net Gross
30” 35 42
SPEED
Low Medium High
Air Capacity (cfm)
124 200 290
Sone
2.0 4.0 5.0
**Specifications subject to change without notice.
background
12
MEASUREMENTS & DIAGRAMS
*** All inch measurements are converted from millimeters. Inch measurements are estimated.
*** All measurements in ( ) are millimeters.
- FOR TOP VENTING -
- FOR REAR VENTING -
background
13
- DIMENSIONS OF THE MODEL -
background
14
PARTS LIST
SERIES: CHX30 SERIES (290 CFM)
NO. DESCRIPTION MODEL /SIZE PART NO.
1
Motor Mounting Plate
Y21-2355-P
2
Hood Frame CHX3030PD (30”)
Y20-1248-Q
3
Recirculating Box
Y36-0228
4
Light socket
GF F005-00000
5
Push Button Control
Y50-0087
6
Light Support
Y20-1273-P
7
Light / Control Panel CHX3030PD (30”)
Y20-1278-Q
8
Light fixture For CFL lighting system
Y53-0441
9
Motor
Y54
-
0005
Y54-0005-1
10
Turbine Impeller
Y23-0049
11
Bottom Casing CHX3030PD (30”)
Y21-2743-6
12
Parametric Panel support clip (Left)
Y23-0041
13
Safety Screen
Y36-0227
14
Magnetic Mechanism
Y23-0040
15
Parametric Panel support clip (Right)
Y23-0042
16
Aluminum Filter
Y23-0043
17
Parametric Panel
Glass Parametric Panel (30”)
PPG30
Stainless Steel Parametric Panel (30”)
PPS30
18
Recirculating Panel
Y21-2732-P
background
15
PART DIAGRAM FOR CHX30 SERIES (290 CFM)
background
16
CIRCUIT DIAGRAM
SERIES: CHX30 SERIES (290 CFM)
For models equipped with Push Control:
background
17
TROUBLE SHOOTING
Issue
Possible Cause
Solution
After
Installation,
both motors
and lights are
not working.
The power is not on. Make sure the circuit breaker and the
unit’s power is ON. Use a voltage meter
to check the power supply.
The wire connection is not secure. Check and tighten wire connection.
The control panel is defective. Replace the control panel.
Lights are
working, but
motor is not.
The motor is defective. Replace the motor.
The capacitor is defective. Replace capacitor.
The control panel is defective. Replace the control panel or processing
board.
The range
hood is
vibrating.
The blower system is not secure. Tighten the turbine impeller/squirrel cage
and air chamber.
The turbine impeller/squirrel cage is
not balanced.
Replace the turbine impeller/squirrel
cage.
Hood is not secured in place. Check the installation of hood, tighten
the mounting bracket.
The motor is
working, but
the lights are
not working.
Light bulb(s) is defective. Try replacing the trouble light bulb(s) to a
working socket, if the bulb(s) still doesn’t
work; replace the halogen light bulb(s).
The light wiring(s) is loose. Check wire continuity from control panel
to light housing(s).
The control panel is defective. Replace the control panel.
The range
hood is not
venting out
correctly.
The range hood is installed outside
of the manufacturer recommended
clearance.
Adjust the clearance, the distance
between the range hoods and cool top,
from 27” to 30”.
There is no make-up air inside the
house.
Open the window to enhance the
performance of the range hood by
creating sufficient make-up air.
Obstacle blocking the pipe work Remove all obstacles from the duct
work.
The pipe size is smaller than the
suggested pipe size.
Change the ducting according to the
manufacturer suggestion.
Cold air is
coming into
the home.
The pipe connection is not properly
sealed.
Check the pipe installation.
background
18
WARRANTY
WARRANTY CERTIFICATE
In order to obtain warranty service, you must provide proof of original purchase from a
KOBE authorized Dealer. Please keep a copy of your original invoice as proof of
purchase.
ONE-YEAR LIMITED LABOR WARRANTY ON KOBE BRILLIA SERIES:
For one year from the date of your original invoice from a KOBE authorized dealer, we will repair any
parts or components free of charge that failed due to manufacturing defects. KOBE reserves the right to
replace, rather than repair the product free of charge at our sole discretion.
It is your sole responsibility to ensure the product is readily accessible for the service technician to
perform repairs. The service technician will not, under any circumstance, remove, alter or modify
any fixture built around and/or connected to the product to gain access to perform repairs.
TWO-YEAR LIMITED PARTS WARRANTY ON KOBE BRILLIA SERIES:
For two years from the date of your original invoice from a KOBE authorized dealer, we will provide non-
consumable replacement parts or components free of charge that failed due to manufacturing defects.
Consumable parts such as lights bulbs, filters, fuses, and oil cups are not covered by this warranty.
WHAT IS COVERED:
This warranty is valid in the United States and Canada. It is non-transferable and applies only to the
original purchaser and does not extend to subsequent owner of this product. In Hawaii, Alaska and
Canada, this warranty is limited. There may be additional shipping charges for parts and service
technician travel costs in remote areas or locations 30 miles outside of KOBE authorized service area.
WHAT IS NOT COVERED:
1. Normal wear and tear, regular service and maintenance required for the product.
2. Consumable parts such as light bulbs, filters, fuses, and oil cups.
3. Chips, scratches or dents due to abuse or misuse of the product, use of corrosive and abrasive
cleaning products.
4. Damages caused by accident, fire, flood and other Acts of God.
5. Services in remote areas or locations 30 miles outside of KOBE authorized service area.
6. Labor cost incurred in connection with the removal of range hood, and reinstallation of
replacement range hood, nor does it cover any other contingent expenses.
7. Scratches inside the hood, back of the baffle filter, and inside the duct cover.
THIS WARRANTY WILL BE VOIDED WHEN:
1. Improper installation and failure to follow installation instructions.
2. Any repair, alteration, modification not authorized by KOBE.
3. Duct alteration, modification and connection.
4. Incorrect electric current, voltage or wiring.
5. Improper usage of the product such as commercially, outdoor or other usage other than its
intended purpose which is residential indoor usage only.
background
19
6. Product is purchased from an unauthorized KOBE dealer.
7. Product is damaged due to negligence, misuse, abuse, accident.
If we determine that the warranty exclusions listed above applies or if you fail to provide all necessary
documentation for warranty service, you will be responsible for all expenses associated with the
requested service, including parts, labor, shipping, travelling, and any other expense related to the
service request.
TO REQUEST WARRANTY SERVICE, PLEASE CONTACT KOBE RANGE HOODS SERVICE
CENTER:
From the 48 contiguous states:
Toll Free: 1-877-BUY-KOBE (289-5623)
E-Mail: customer.service@koberangehoods.com
From Alaska, Hawaii, and Canada:
TEL: 1-626-775-8880
E-Mail: customer.service@koberangehoods.com
background
20
WARRANTY INFORMATION FORM
Fill in the blanks and keep this paper with the original invoice in a
safe place for future service purpose.
1. Date of purchase :
2. Model No. :
3. Serial No. :
For warranty service or spare parts purchase contact:
KOBE Service Center (USA ONLY)
Toll Free: 1-877-BUY-KOBE (289-5623)
Email: customer.service@koberangehoods.com
For service in Canada and to report a problem, please
contact:
Phone: 1-626-775-8880
Email: customer.service@koberangehoods.com
Your notes:
background
KOBE Range Hoods
11775 Clark Street
Arcadia, CA 91006 USA
www.koberangehoods.com
This KOBE hood is made for use in the USA and CANADA only. We do not recommend
using this hood overseas as the power supply may not be compatible and may violate the
electrical code of that country. Using a KOBE hood ove
rseas is at your own risk and
will void your warranty.
Cette hotte KOBE est fabriquée pour usage aux États-
Unis et au Canada seulement. Il
n’est pas recommandé d’utiliser cette hotte à l’étranger puisque l’alimentation électrique
pourrait ne pas être compatible et enfreindre le code de l’électricité de ce pays.
L’usage
de la hotte KOBE à l’étranger est à votre propre risque et la garantie sera annulée.
Esta campana de extracción KOBE
ha sido fabricada para ser utilizada únicamente en
EE.UU. y CANADÁ.
No recomendamos la utilización de esta campana en el extranjero
debido a que la fuente de energía podría no ser compatible y podría violar el código
eléctrico de dicho país. Utilizar una campana KOBE
en el extranjero será a su propio
riesgo y anulará la garantía.
VER. 170301
Information subject to change without notice.

Specifications

Indexed Terms: Range Hood

Kobe CHX30 Questions and Answers