Napoleon P500RSIBNSS-3-GR PRESTIGE® 500 RSIB WITH INFRARED SIDE AND REAR BURNERS

Owner's Manual - Page 7

For P500RSIBNSS-3-GR. Series: PRESTIGE SERIE
Also, The document are for others Napoleon models: P665*, P500*, P500-PHM*

PDF File Manual, 24 pages, Read Online | Download pdf file

P500RSIBNSS-3-GR photo
Loading ...
Loading ...
Loading ...
Getting Started |
7
Napoleon.com | Prestige
®
Series
Getting Started
WARNING! Check the hose for evidence of excessive abrasion, melting, cuts or cracks. If the hose is damaged,
it must be replaced with an assembly specifically recommended by Napoleon.
!
GRILLING
PRO TIP!
Get inspired to create
delicious meals from the
recipes and grilling
techniques at
www.napoleon.com and
Napoleon’s cookbooks.
Technical Data
The following table lists gross heat input, gas usage values and orifice sizes corresponding to each burner per Gas Category:
ORIFICE SIZE GROSS HEAT INPUT (TOTAL) GAS USAGE (TOTAL)
I II
I II I II
P500
MAIN
#60 1.45mm 16 kW 14 kW 1164 g/hr 1334 L/h
REAR
1.25mm #50 5.7 kW 5 kW 415 g/hr 476 L/h
SIDE FLAME
#60 1.45mm 4 kW 3.5 kW 291 g/hr 333 L/h
SIDE INFRARED
#60 1.45mm 4 kW 3.5 kW 291 g/hr 333 L/h
P665
MAIN
# 60 - 20 kW - 1455 g/hr
-
REAR
1.25mm - 5.7 kW - 415 g/hr
-
SIDE FLAME
#60 - 4 kW - 291 g/hr
-
SIDE INFRARED
#60 - 4 kW - 291 g/hr
-
The following table lists all certified gases and pressures. Verify the information on the rating plate corresponds with this list.
Note: Only use regulators that supply the pressure listed here.
Gas Category
I
3B/P(30)
I
3+(28-30/37)
I
3B/P(37)
I
3B/P(50)
I
2H
I
2E
I
2E+
I
2L
Orifice Sizes I I I I II II II II
Gases / Pressures
Butane /
Propane
30mbar
Butane
28-30mbar
Propane
37mbar
Butane /
Propane
37mbar
Butane /
Propane
50mbar
G20 at
20mbar
G20 at
20/25
mbar
G20/G25
at 20/25
mbar
G25 at
25mbar
Countries
AL, BE, BG,
CY, CZ, DK,
EE, FI, FR,
GB, GR,
HR, HU,
IS, IT, LT,
LU, MT,
NL, NO, PL,
RO, SE, SI,
SK, TR
BE, CH, CY,
CZ, ES, FR,
GB, GR, IE,
IT, LT, LU,
LV, PL, PT,
SI, SK, TR
BE, CH, CZ,
ES, FR, GB,
GR, HR,
HU, IE, IT,
LT, NL, PL,
PT, RO, SI,
SK, TR
AT, CH, CZ,
DE, SK
AT, BG,
CH, CZ,
DK, EE,
ES, FI,
GB, GR,
HR, HU,
IE, IS, IT,
LV, LT, NO,
PT, RO,
SE, SI,
SK, TR
DE, LU,
PL
BE,FR NL
Orice Size
Side (Infra Red)
Side (Flame)
Cered Gases / Pressures - Check rang plate to ensure that it corresponds with following list.
Do not tamper with or modify regulator. Use only regulator which supply the pressure listed in the table above.
The grill is also equipped with an internal regulator. This internal regulator has an outlet pressure of 24.5 mbar for
propane/butane and 18.5 mbar for natural gas and must not be modied or adjusted. For replacement, use only the
regulator specied by the manufacturer.
Orice Size
Side (Infrared)
Side (Flame)
Cered Gases / Pressures - Check rang plate to ensure that it corresponds with following list.