* If local codes permit, use flexible
stainless steel tubing (Design Certified
by the American Gas Association) to
connect your dryer to the gas supply
line. To prevent kinking, you may need
an elbow and connector between the
stainless steel tubing and the dryer
gas pipe. The gas pipe that comes
out through the rear of your dryer has
a 3/8-inch male pipe thread.
U
* A combination of pipe fittings must
be used to connect the dryer to the
existing gas line.
3/8-inchmale l/B-inch HPT
threaded pipe pluggedtapping
connection
Gas shut-
Reducer or 1/2-inchgas off valve
connector supply line
* The gas supply must have a shut-off
valve. The valve should be in the same
room as the dryer, within six feet. The
location should be easy to reach for
opening and closing the valve.
* A 1/8-inch NPT plugged tapping, acces-
sible for test gauge connection, must
be installed immediately upstream of
the gas supply connection to the dryer.
* To ensure proper combustion and
ventilation, the dryer installation should
adhere to the minimum recommended
clearances. See page 11.
* For mobile home installation, see
page 12 for more instructions.
* The dryer must be disconnected from
the gas supply piping system during
any pressure testing of that system at
test pressures in excess of 1/2psig.
3/8-inchmale threaded
pipe connection
1/2-inchto 3/g-inch
pipe reducer
I5