- 11 -
09/2020
Copyright © 2020, Fast ČR, a.s.
If you turn the appliance on or off, while the automatic start or shut-off is set, the
appliance will automatically cancel the start or shut-off function.
If the message "P2" appears on the display B10, the automatic start / shut-off
function will be cancelled.
Full condensate tank indicator
When the indicator light B11 is lit on the control panel A1, the condensate tank A4
is full and the condensate needs to be emptied out. The appliance will stop running.
Empty out the condensate tank A4 according to the instructions in chapter
"Draining condensate into the tank" After installing the condensate tank A4 the
appliance will automatically start up again.
Automatic defrosting
In the event that frost forms around the vaporizer coil, the appliance will
automatically switch to the automatic defrost mode until it eliminates the frost.
In this mode, the compressor will turn on in regular intervals and the fan will run
continuously.
DRAINING CONDENSATE
For draining condensate, either the tank A4 or the drain hose A6 may be used.
Draining condensate into the tank
Prior to turning on the appliance, check that outlet A6 is fitted with aplug.
During operation, condensate will accumulate in the tank A4. As soon as it fills up,
the indicator light B11 will be lit and the appliance will turn off automatically. Error
message "P2" will appear on the display B10.
Carefully slide out the condensate tank A4, careful not to spill any water. The bottom
of the condensate tank A4 is not level, therefore do not stand it on the floor when
the condensate tank A4 is full. Empty out the condensate tank A4 and insert it back
into the appliance. Check that the condensate tank A4 is correctly installed. The
appliance will automatically resume operation.
When removing the condensate tank A4, be careful so as not to drop it and damage
the internal parts of the appliance. Do not use excessive force when installing
the condensate tank A4 into the appliance. Using brute force may damage the
appliance.
If there is any water in the installation area of the condensate tank A4, wipe it using
adry wiping cloth.
Continuous condensate draining via the drain hose
For continuous draining of condensate, screw off the plastic plug anticlockwise from
the drain hose outlet A6. Carefully store the plug for future use.
Note:
If there is water in the outlet when the plug is removed, wipe it using
adry wiping cloth.
Properly screw in the threaded end of the drain hose A6 to the outlet. To ensure that
condensate does not leak, check that the hose end is properly screwed in.
Locate the free end of the hose so that the condensate can flow out freely. The
container or place where the condensate is drained must be lower than the outlet
A6. Do not bend or twist the hose.
Set the required humidity and fan speed to start the appliance.
Note:
When not using the drain hose for continuous draining of condensate,
screw off the hose, wipe away nay water and close the outlet A6 using
the plug.
CLEANING AND MAINTENANCE
Disconnect the power plug from the power socket before cleaning.
Note:
For cleaning, do not use cleaning products with an abrasive effect,
solvents, etc. that could damage the appliance.
Warning:
To prevent the risk of injury by electrical shock, do not submerge
the appliance, power cord or power plug in water or any another
liquid.
Cleaning the condensate tank
Empty out the condensate tank A4 whenever you finish using the appliance and
wipe it using awiping cloth.
To prevent undesirable bacteria, micro-organism or moulds from multiplying
inside the tank A4, clean it out at least once per month using acloth dampened in
lukewarm water with the addition of neutral detergent. Then rinse it out thoroughly
using clean water, wipe it dry and insert it back into the appliance.
Do not wash the tank A4 in adishwasher.
Cleaning the air filter
Release the grille A8 and then carefully remove the filter A9. Wash the filter A9
in warm water with asmall amount of kitchen detergent. Then thoroughly rinse
it under running water and allow it to dry naturally. Install the filter A9 back in its
place. However, first make sure that the filter A9 is completely dry. Then reattach
the grille A8.
Warning:
Do not use the appliance without the filter A9 being properly
installed. Never wash the filter A9 in adishwasher.
Cleaning the outer cover and air outlet grilles
To clean the air outlet grille A3, the air inlet grille A8 and the outer cover, use
awiping cloth lightly dampened in lukewarm water with asmall addition of neutral
detergent. Make sure that water does not enter into the vents. In the event that
grilles A3 and A8 are only dusty, avacuum cleaner may be used to clean them.
Storage
When not using the appliance for an extended period of time, disconnect the power
plug from the power socket and clean it according to the instructions provided
above.
Clean the condensate tank A4 only 24hours after turning the appliance off since
even during this time asmall amount of condensate may accumulate.
Wind the power cord around the holder.
Store the appliance in a dry, clean and well-ventilated location not exposed to
extreme temperatures and out of children'sreach.
TROUBLESHOOTING
Problem Solution
The dehumidifier
cannot be turned
on.
Check that the power cord plug is correctly connected to
apower socket.
Check that fuses are in order.
The dehumidifier reached the set humidity level or the
condensate tank A4 is full.
The condensate tank A4 is not correctly installed.
The dehumidifier
is not removing
humidity from the
room.
The dehumidifier has only been running for ashort time,
please wait afew more moments.
Make sure that there are no curtains, roller blinds or furniture in
front of the dehumidifier.
The humidity setting is insufficient.
Check that the doors, windows and other openings in the room
are properly closed.
The temperature in the room is too low (below 5°C).
There is an oil heater or other appliance located in the room
that may be creating humidity.
The dehumidifier
is too noisy while
running.
The air filter is clogged.
The dehumidifier is tilted.
The floor is not level.
Frost is forming
inside the
appliance.
The dehumidifier is equipped with an automatic defrost
function, which is activated when frost starts to form.
There is water on
the floor.
Check the hose for damage and that it is correctly attached.
Disconnect the hose and use the condensate tank A4 to drain
the condensate. Close outlet A6 using aplug.
Error messages
Error messages
on the display
Meaning Solution
AS Humidity sensor error Disconnect the power plug from the
power socket and reconnect it.
If the problem persists, please
contact an authorised service centre.
ES Vaporizer heat sensor
error
Disconnect the power plug from the
power socket and reconnect it.
If the problem persists, please
contact an authorised service centre.
P2 The condensate tank
A4 is full or incorrectly
installed.
Empty out the condensate tank A4
or install it correctly.
Loading ...