GE - General Electric RAK364R1 GE Strip Heat Receiver

User Manual - Page 2

For RAK364R1.

PDF File Manual, 36 pages, Read Online | Download pdf file

RAK364R1 photo
Loading ...
Important safety information.
Specifications.
WARNING!
RISK OF ELECTRIC SHOCK. Can cause injury or death: Turn off power at the
main service panel by removing the fuse or switching the appropriate circuit
breaker to the OFF position before installing the thermostat receiver.
GE IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED
MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT.
THIS EQUIPMENT COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT
TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
• Do not use air conditioning when the outdoor temperature is below 50 degrees; this can
damage your A/C system and cause personal injuries.
• Use this thermostat only as described in this manual.
Before you begin – Read all instructions before using device. Follow all warnings and cautions.
SAVE THESE INSTRUCTIONS
Electrical ratings: • Thermostat: DC Power 3.0 VDC (4 “AA” batteries included)
• Receiver: 24 VAC (18–30 VAC); 120 mA
Operating temperature range: 40°F–99°F (4°C–37°C)
Temperature set range
Heat mode: 50°F (10°C)–84°F (29°C)
Cool mode: 64°F (18°C)–99°F (37°C)
Resolution: ± 1°F (± 1.0°C)
System configurations: RAK348R1 receiver – 2-stage heat (heat pump/resistance heat);
RAK364R1 receiver – 1-stage heat (resistance heat); 1-stage cool
Timing: Anti-short cycle: 3 minutes (minimum compressor off time)
Terminals: R, GL, GH, B, Y, W, C
2