Performance Data Sheet
SmartWater FiltrationSystem
GWF/ HWF Cartridge
This system has been testedaccordingto NSF/ANS142/53for reductionof the substances listed below.
The concentrationof the indicated substances in water enteringthe system was reducedto a concentration
less than or equal to the permissiblelimit for water leaving the system, as specified in NSF/ANS/ 42/53.*
(100%safety factors built in for unmetered usage)
Parameter
Chl()fine
T&,O
Particulate" =
USEPA
MCL
Standard No. 42: Aesthetic Effects
Influent Effluent
Challenge Concentration Average Man.hUm
2.0 mg/L + 10% 0.02 ppm 0.05 ppm
at least 10,000 particles/mL 3,978 7,800
% Reduction
Average Minimum
98.90% 97.37%
98.00% 96.10%
Min. Required
Reduction
>_5O%
>_85%
Standard No. 53: Health Effects
Parameter Effluent
Average Maximum
Tm'bidity 0.07 NTU 0.1 NTU
Cysts 2(5 55
[,ead at pH 6.5 1 ppb 1 ppb
Lead at pH 8.5 1.8 ppb 4.3 ppb
[ kldane 0.00005 ppm 0.00005 ppm
Au'azine 0.002 ppm 0.003 ppm
2,4-D 0.042 ppm 0.090 ppm
A_bestos 0.32 MFL/ml 1.2 MFL/ml
USEPA
MCL
1 NT[) 'I:'I:*
99.95% Reduction
15 ppb
15 ppb
0.0002 ppm
0.003 ppm
0.100 ppm
9(.)%
Influent
Challenge Concentration
11 +_1 NTU *'_:*
Minimum 50,000 L
0.15 mg/i,_+ 10%
0.15 mg/i,_+ 10%
0.002 mg/L _+ 10%
0.009 mg/i, _+10%
0.210 mg/L _+ 10%
I(F to 1()s fibers/I_;
fibers gTeater than
10 micrometers in length
% Reduction
Average Minimum
99.71% 99.59%
99.97% 99.95%
99.37% 99.37%
98.8% 97.13%
91.93% 91.93%
76.19% 64.28%
84.89% 67.63%
99.95% 99.82%
Min. Requked
Reduction
0.5 NTU
>99.95%
0.010 mg/L
0.010 mg/i,
0.0002 mg/L
0.003 mg/i,
0.07 mg/L
99%
Testedusing a flow rate of O.5 gpm;pressureof 60psi); pH of 7.5+_O.5; temp. of 20° +_2.5°C
** Measurementin Particles/ml.Particlesusedwere0.5-1microns
*** NTU=NephelometricTurbidityunits
Operating Specifications
* Capacity: certified for up to 300 gallons (1135 1); up to six months for models without a replacement filter indicator light;
up to one year fbr models with a replacement filter indicator light
, Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
, Temperature: 33-100°F (0.('_38°C)
, Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
* Flush new cartridge at fhll flow for 3 minutes to purge out trapped air.
, Replace cartridge when flow becomes too slow.
Special Notices
* Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
, This drinking water system umst be maintained according to manuf_cturer's instructions, including replacement of filter
cartridges.
, Do not use with water that is microbiologically unsafe or of tmknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
* The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your
water.
Check fbr compliance with the state and local laws and regulations.
Note that while the testing was perfbrmed under standard laboratory conditions, actual performance may vat> Systems
must be installed and operated in accordance with manufi_cturer's recommended procedures and guidelines.
SysteiTQ Tested and Certified b) NSF International against ANSI/NSF Standard 42 & 53 lot
tt_e reduction of..
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Red uction
Mechanical Fihration Unit
Particulate Red uction, (;lass ]
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidit} Reduction
(;)st and Asbestos Reduction
Mantdacmred for: General Elecu'ic Compan), [xmisville, KY 40225