Installation
Installation
The undermount rangehood must be installed at the correct distance above the cooktop (650mm minimum -
750mm recommended).
Cut a hole in the cabinet to fit the rangehood (RPD3CL6WH, RPD3CL6BK 500x275mm, RPD3CL9WH,
RPD3CL9BK 880x275mm) centred above the cooktop. The hole edge should be at least 35mm from any
cupboard edge.
Take the plastic Ø150mm outlet adaptor and screw it over the square hole at the top of the appliance using the
four supplied ST4x8mm screws. Check that the two half-circle flaps open outwards freely (these act as a one-way
valve).
Remove the bottom facia panel by removing the four M4x10mm screws and lifting the panel away. Push the
appliance up into the hole and hold in place. Tighten the M4x45mm bracket screws (see diagrams below) until
the rangehood is fully secured in the cabinet. Fix the bottom fascia panel back to the rangehood using the original
M4x10mm screws.
Cut a ventilation/flue hole in the cupboard (size and position will depend on the ducting method chosen).
RPD3CL6WH, RPD3CL6BK
RPD3CL9WH, RPD3CL9BK
Warning: Failure to install the screws or fixing devices in accordance with the instructions may result
in an electrical hazard.
in recirculation mode where ducting is not a
chosen/desired or practical option. Ducting may
still be required to vent air from a cupboard
cavity. Ensure that the top ducting outlet is not
the efficiency of the rangehood.
When used as a recirculating rangehood, the
aluminium filters must be supplemented with
charcoal filters. The filter is attached to the
aluminium filter with the metal strips.