Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from refrigerator.
Failure to do so can result in death, explosion, or fire.
To ensure proper ventilation for your refrigerator, allow for a V2"
(1.25 cm) of space on each side and at the top. Allow for a 1"
(2.54 cm) space behind the refrigerator. If your refrigerator has an
ice maker, allow extra space at the back for the water line
connections. When installing your refrigerator next to a fixed wall,
leave a 33/4'' (9.5 cm) minimum space between the refrigerator and
wall to allow the door to swing open.
NOTE: It is recommended that you do not install the refrigerator
near an oven, radiator, or other heat source. Do not install the
refrigerator in a location where the temperature will fall below 55°F
(13°C).
1/2" (1.25 cm)
]L
33/4" (9.5 cm)
i
/
\_
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended Grounding Method
A 115 Volt, 60 Hz., AC only 15- or 20-amp fused, grounded
electrical supply is required. It is recommended that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, turn Cooling OFF, and then disconnect the
refrigerator from the electrical source. When you are finished,
reconnect the refrigerator to the electrical source and turn Cooling
ON. See "Using the Controls."
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
TOOLS NEEDED:
Flat-blade screwdriver 1A" Nut driver
7A6"and V2" Open-end or two _A" Drill bit
adjustable wrenches Cordless drill
IM PO RTANT:
All installations must meet local plumbing code requirements.
Do not use a piercing-type or 3A6"(4.76 mm) saddle valve
which reduces water flow and clogs more easily.
Use copper tubing and check for leaks. Install copper tubing
only in areas where the household temperatures will remain
above freezing.
For models with water filters, the disposable water filter
should be replaced at least every 6 months.
Water Pressure
A cold water supply with water pressure of between 35 and
120 psi (241 and 827 kPa) is required to operate the water
dispenser and ice maker. If you have questions about your water
pressure, call a licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 35 and 120 psi (241 and
827 kPa).