c. Lift the left and right panel up and out of the unit.
Left
Panel
Right
Panel
d. Remove y ash.
It is possible that creosote may accumulate in the exhaust
fan therefore, this must be brushed clean. The exhaust fan
can be found behind the left side panel (facing the front
of the heater), the circulation fan can be found behind the
right side panel. To access the igniter, remove the air inlet
tube and cover (2 screws). The auger motor is located in
the center rear of the unit. Note: When cleaning, take care
not to damage the fan blades.
If a vacuum is used to clean your stove, we suggest
using the AV15E AshVac vacuum. The AV15E AshVac is
designed for ash removal. Some regular vacuum cleaner
(i.e. shop vacs) may leak ash into the room.
DO NOT VACUUM HOT ASH.
WARNING:
FAILURE TO PROPERLY MAINTENANCE THE CLEAN
OUTS WILL RESULT IN POOR PERFORMANCE OF
THIS STOVE.