Smeg TR90X9-1 Cooker with Gas Hob 90x60 cm

User Manual - Page 45

For TR90X9-1.

PDF File Manual, 54 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Installation
101
EN
The nozzles not provided are available at Authorised Service Centres.
6 LPG G30/31 AUX SR R DUAL int. DUAL ext.
Rated heating capacity (kW)
1.0 1.8 3.0 0.9 3.8
Nozzle diameter (1/100 mm)
50 65 85 44 96
Pre-chamber (printed on nozzle)
--- - -
Reduced flow rate (W)
400 500 800 400 1300
Rated flow rate G30 (g/h)
73 131 218 65 276
Rated flow rate G31 (g/h)
71 129 214 64 271
7 LPG G30/31 AUX SR R DUAL int. DUAL ext.
Rated heating capacity (kW)
1.1 1.9 3.0 0.8 3.9
Nozzle diameter (1/100 mm)
50 65 81 42 93
Pre-chamber (printed on nozzle)
--- - -
Reduced flow rate (W)
450 550 900 450 1500
Rated flow rate G30 (g/h)
80 138 218 58 284
Rated flow rate G31 (g/h)
79 136 214 57 279
8 LPG G30/31 AUX SR R DUAL int. DUAL ext.
Rated heating capacity (kW)
1.0 1.8 3.0 1.0 3.9
Nozzle diameter (1/100 mm)
43 58 74 43 75
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (H2) (S1)
Reduced flow rate (W)
400 500 1000 400 1500
Rated flow rate G30 (g/h)
73 131 218 73 284
Rated flow rate G31 (g/h)
71 129 214 71 279
9 Town gas G110 AUX SR R DUAL int. DUAL ext.
Rated heating capacity (kW)
1.0 1.75 2.8 1.0 3.2
Nozzle diameter (1/100 mm)
145 185 260 145 300
Pre-chamber (printed on nozzle)
(/8) (/2) (/3) (0040) (0190)
Reduced flow rate (W)
400 500 800 400 1000
Loading ...
Loading ...
Loading ...