4.4.8 Filter Life Reset
1. To reach the Filter Life Reset function from the main display window, press
the Menu key seven times.
2. Press and hold the Enter key until the ashing cursor appears.
3. Press the p key to select the lter that has been replaced.
4. Press the Enter key to conrm that the selected lter has been replaced. To
safeguard against inadvertently resetting the life of the wrong lter, the
selection needs to be reconrmed. The Filter Life LED for the appropriate
lter is now ashing red. Note: If the wrong lter has been selected, or if
you wish to exit the enter mode, press the Menu key. This leaves the Filter
Life Reset unaffec ted.
5. To conrm the lter change and exit the Filter Life Reset display window,
press the Enter key.
6. Upon successful reset of the lter life, the new remaining lter life (taking
the currently selected fan speed and programmed lter load indices into
account) will be displayed.
4.4.10 Language Setting
The Language Menu Display allows to change the systems display language.
1. To reach the Language Menu Display from the main display window, press
the Menu key ten times. The current display language is displayed.
2. To change the display language, press and hold the Enter key until the
cursor starts to ash.
3. Use the p key to scroll through the display language options.
4. Press the Enter key to save the desired display language and to exit the
enter mode.
18
Chapter 4 – Using the Control Panel
4.4.9 Changing the Airow Units
N.B. The air delivery (airow units) displayed in this manual are examples only
and will vary according to model.
1. You can change the air volume units from cubic feet per minute (cfm) to
cubic meters per hour (m
3
/h), and vice versa, by pressing the Menu key
eight times and then the Enter key for three seconds.
2. When the rst character of the air volume units starts to ash, press the p
key once to change the units.
3. Press the Enter key to conrm the air volume unit change. Until modied
again, the airow rate will now be displayed in the newly selected units.
The Filter Life Reset function allows the lter life counter to be reset after a new lter has been inserted. As a result,
the appropriate lter life LED on the control panel will be reset to green and the hour count in the Filter Life Reset
display will be reset to the full life span of the new lter.