INSTALLATION
15
ENGLISH
Subbase (Optional)
The Subbase provides an enclosure for an electrical receptacle, power switch and a circuit breaker. Electrical
connections to the power supply from the unit are made inside the subbase. In addition, the subbase provides
structural support to the Wall Sleeve and to the weight of the PTAC unit .
The Subbase kit consists of two leveling legs for sleeve support and an accurate unit for leveling during instal-
lation. Also, the subbase is pre-wired and is grounded by means of a grounding screw.
Part No.: AYSB1201B Subbase - 208/230V 20A w/o DS
AYSB1301B Subbase - 208/230V 30A w/o DS
AYSB5101 Subbase Panel
AYSB6101 Subbase - Non Electrical
Notes :
w/o DS --> without disconnect switch
w/ DS --> with disconnect switch
NOTE
When using a subbase, the wall sleeve must be installed at a minimum height of 3 – 1/4 inches (83mm) above
a finished floor and at a minimum distance of 2 – 3/4 inches(70mm) from a finished wall.
Side Extension
Panel (2)
Leveling
Bolt
Electrical
Subbase
Access Cover
Leveling Bolt
Hole to Attach
Subbase to Sleeve (2)
Receptacle
Electrical Junction Box