4. Do not dismantle or modify the device, serious accidents may happen when
dismantling or modifying.
5. Do not open the appliance enclosure. The appliance contains high pressure
electric circuit, electric shock may occur when dismantling the frame.
6. Unscrew the plug and cut off the power when cleaning.
7. Do not spray water directly to the product when cleaning. Water can conduct
electricity, thus electric leakage may cause electric shock.
8. Do not pat the product and put heavy object onto the product.
9. Abnormal operation may cause damage and danger.
10. High temperature may cause scald.
11. Do not touch the appliance directly with hand due to high temperature during or
after the operation.
12. When the thunderstorm is coming, cut off the power supply asap to avoid damage
done by the lighting stroke
13. Do not destroy the control panel with hard or sharp objects.
14. After working, disconnect it from power.
15. All the servicing work would be dangerous for people other than qualified
personnel.
16. If the supply cord is damaged, to avoid danger, the substitution work should be
done by the manufacturer, its maintenance department or similar professional
personnel.
5. Using Instructions
1. Check all the parameters and installation before using. Only use it when
everythings correct.
2. When cooking, please wear athermic gloves. To avoid burnings, do not touch the
device enclosure.
3. When the device is powered on, if the proportioner knob is in a position shown in
figure <1>, the heating indicator is off and the elements are not working. Rotate
the knob, the indicator will be on and the device is working with the power.
4. Turn the knob clockwise just like shown in figure <2>, the heating elements start
to work in a way of intermittent operation and the working power will increase as
the rotation angle increases. When the temperature reaches the desired value,
the elements will stop working (the indicator turns off at the same time); when the
chamber temperature drops, the device will heat up automatically (while the
indicator turns on again); the device works in such a circulation to keep the
chamber temperature at a constant set temperature. And when the knob is in the
position of figure <3>, the heating elements work continuously without interruption.
Continue to rotate the knob clockwise to OFFposition, the device stops
working. If rotate the knob anticlockwise, the device will work conversely.