Gas Supply Line:
• Must include 1/8" NPT minimum plugged tapping accessible for test gauge connection,
immediately upstream of the gas connection to the dryer. See illustration.
• 1/2" IPS pipe is recommended.
• 3/8" approved aluminum or copper tubing is acceptable for lengths under 20 ff (6.1 m) if
local codes and gas supplier permit.
• If you are using Natural gas, do not use copper tubing.
• kengths over 20 ff (6.1 m) should use larger tubing and a different size adapter fitting.
• If your dryer has been converted to use LP gas, 3/8" I.P compatible copper tubing can be
used. If the total length of the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds that resist the action of IP gas must be used. Do not use
TEFLON '_tape.
• Must include a shutoff valve:
In the U.S.A.:
An individual manual shutoff w_lve must be installed within six (6) feet (1.8 m) of the dryer
in accordance with the National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shutoff valve must be installed in accordance with the B149.1,
Natural Gas and Propane Installation Code. [t is recommended that an individual manual
shutoff valve be installed within six (6) feet (1.8 m) of the dryer.
The location should be easy to reach for opening and closing.
A C E
B D
A. _" flexible gas connector
B. _" pipe to flare adapter fitting
C. _" NP I minimum plugged tapping
D. _//' NPT gas supply line
E. Gas shutoff valve
Gas supply connection requirements
• Use an elbow and a %" flare x %" NPT adapter fitting between the flexible gas connector
and the dryer gas pipe, as needed to avoid kinking.
• Use only pipe-joint compound. Do not use FEFI.ON _÷*tape.
• [his dryer must be connected to the gas supply line with a listed flexible gas connector
that complies with the standard for connectors for gas appliances, ANSI Z21.24 or
CSA 6.10.
_-f_TEFLON is a registeued trademark of E.I. Du Pont De Nemours and Company.
Burner Input Requirements:
Elevations above 10,000 ft (3,048 m):
• When instal led above 10,000 ft (3,048 m) a 4% reduction of the burner Btu rating shown
on the model/serial number plate is required for each ,000 ft (305 m) increase in
elevation.
Gas supply pressure testing
• The dryer must be disconnected from the gas supply piping system during pressure testing
at pressures greater than % psi.
Dryer Gas Pipe
• The gas pipe that comes out through the rear of your dryer has a %" male pipe thread.
A
(23.5cm)
A. a_,, NPT dryer pipe
VENTI NG REQU I REMENTS
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: lb reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
[he dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a
concealed space of a building.