Sierra Flame PALISADE36LP Palisade Series Vent Free Liquid Propane Fireplace

User Manual - Page 29

For PALISADE36LP.

PDF File Manual, 60 pages, Read Online | Download pdf file

PALISADE36LP photo
Loading ...
Loading ...
Loading ...
Page 29 of 60
VENT RESTRICTOR INSTALLATION
VENT RESTRICTOR
To fasten the Restrictor Plate to the ceiling of the firebox:
1/. Remove the 2 screws that are in place
2/. Remove portion of restrictor for your correct air flow
3/. Fasten Restrictor Plate back in place.
VENT
RESTRICTOR INSTALLATION (continued)
The restrictor plate is included loose in the bottom of your fireplace. The restrictor plate comes factory
set at 60% with 3 portions. For 40% restriction, break off one side of the restrictor plate. For 20%
restriction, break off both sides of the restrictor plate. For 0 restriction do not install.
No restrictor
0 10’
20% restrictor
10 18’
40% restrictor
18 26’
60% restrictor
26 34’
NOTE
ALLOWING THE VENT PIPE TO SLOPE DOWN TOWARDS THE VENT TERMINATION COULD
CAUSE POOR COMBUSTION AND/OR HIGH TEMPERATURES THAT MAY PRESENT A FIRE
HAZARD.
PERMETTRE LA tuyau de ventilation vers descendent vers la sortie de ventilation POURRAIT
PROVOQUER une mauvaise combustion et / ou de températures élevées qui peuvent présenter
des risques d'incendie.
Vent Configuration
Restrictor Size
Factory set
60%
Remove 1 side
40%
Remove 2 sides
20%
Loading ...
Loading ...
Loading ...