Loading ...
Loading ...
INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS FOR COOKER HOOD MODEL IVX45
230-240 Vac - 50 Hz
Exhausting cooker hood. The equipment is constructed in accordance with European Standards and with the requirements included in the following Directives: 2006/95EC ( Low Voltage
Directive), 2004/108 (Electromagnetic Compatibility).
PRESENTATION
The equipment (Picture 1 ) is made of the following items :
1) Cooker hood body
2) Telescopic chimney
INSTALLATION
Read the instruction manual before installing and/or using the hood.
The unit must be fitted at a distance of at least 65 cm. from the cooking hob. If the
mounting instructions of the gas cooker indicate a wider distance, respect it. The unit must
not be mounted above cookers fitted with top radiant plate.
Respect all the air discharge regulations.
The air must not be discharged in a pipe used to discharge exhaust fumes produced by
gas-fed equipments or fuel-fed equipments (this does not apply to filtering hoods).
The room must be adequately ventilated when the hoods is used together with other gas-
fed or fuel-fed equipments.
For an easy access, it is advisable to move possible furniture under the installation area.
Installation of the hood onto the wall.
The hood is equipped with all the necessary fastenings for its installation, which are
suitable for most surfaces. Anyway ask a professional to verify that the installation surface
is strong.
Installation must be carried out by qualified installers according to present regulations.
After having drawn and drilled the wall as in picture 2, use the following fastenings for
installation:
Blocking dowels (A)
Suspending and levelling dowels (B)
Brackets and screws for fixing the chimney to the wall (C)
ELECTRICAL CONNECTIONS
This equipment must be connected to a grounding plant.
Two types of electrical connection can be used:
1) Using a standard plug to be connected to the power cable and inserted in a mains
socket which must be accessible (so that the plug can be disconnected when
servicing is carried out). Make sure that the plug is accessible also after the
complete installation of the equipment.
2) By means of a fixed mains connection, fitting a bipolar switch, which ensures the
disconnection, with an opening distance of the contacts allowing a complete
disconnection on the conditions of the overvoltage III category, according to
installation regulations. The ground connection (yellow-green wire) must not be
interrupted.
Refer to the plate inside the hood for the mains voltage and frequency ratings.
EMPLOYMENT
This cooker hood can be employed as exhausting or filtering.
Exhausting (external evacuation). Kitchen smokes are driven outside through a flue
joined to the exhaust pipe flue connector.
This pipe must not under any circumstances be connected to cooker, boiler or burner
exhaust pipes, etc.
Filtering (inside recycling). Smokes pass through the activated charcoal filter (Picture 3 -
D) to be cleaned and recycled in the kitchen environment by means of holes (E) from
which the purified air will come out. These holes have to be free and communicating with
the kitchen environment.
In this case you should not install the exhaust pipe without curve.
OPERATION
The hood is supplied with a multispeed motor.
The hood should be run at low speed under normal conditions and at higher speeds only
when there is a heavy build-up of fumes or odours.
Ideally, the hood should be switched on as soon as cooking is started and then kept on
until all odours have been eliminated.
The controls consist of these commands. Press TL to turn on the light, press T1 to swich
on the hood at first speed and to switch off the aspirator, press T2-T3-T4 to select
functioning speeds.
By pressing of the command T1 the motor starts running at the 1
st
speed. The commands
T2-T3-T4 switch the motor on respectively at the 2
nd
, 3
rd
and 4
th
speed. In order to switch
the motor off press T1 once if set at the 1
st
speed, twice if set at the 2
nd
, 3
rd
and 4
th
speed.
Adjustable and delayed self switching off
While the hood is working, keep the TL command pressed until all leds start blinking.
By pressing one of the commands (T1, T2, T3, T4) you can program the delayed self
switching off, as follows:
T1 corresponds to 5 minutes
T2 corresponds to 10 minutes
T3 corresponds to 15 minutes
T4 corresponds to 20 minutes
While the self switching off is in function, it is possible to modify the speed previously set.
If the same command corresponds both to the time of delayed self switching off and to the
speed, then the led blinks; if the commands are different, the speed led has a fixed light.
Filters maintenance reminder
Aluminium anti-grease filters
Once the hood is switched off, after 30 hour functioning, all the leds of the speed buttons
switch on with a fixed light for 30 seconds to remind that aluminium anti-grease filter need
cleaning.To set the timer to zero keep the button T4 pressed with the aspirator switched
off, otherwise the timer will remain set on 30 hour functioning and the reminder will occur
again when the hood is switched off again.
Charcoal filter (for filtering hoods)
Once the hood is switched off, after 120 hour functioning, all leds blink for 30 seconds to
remind that the charcoal filter need cleaning.
To set the timer to zero keep the button T4 pressed with the aspirator switched off,
otherwise the timer will remain set on 120 hour functioning and the reminder will occur
again when the hood is switched off again.
MAINTENANCE
Always disconnect the hood from the mains before carrying out any maintenance or
cleaning operation.
Particular attention should be paid to the metallic anti-grease filters that are designed to
trap particles of fat contained in the fumes. The metallic anti-grease filters must be washed
at least once a month with detergent in hot water (or in the dish-washer).
ATTENTION: the grease collected in the filters can easily catch fire and it is therefore
extremely important to clean the metallic filters on a regular basis as per instructions.
The activated charcoal filters are designed to collect unpleasant odours in the cooking
fumes. The air is then released purified in the environment. The charcoal filters must not
be washed, but replaced 2 or 3 times a year, depending on how much the hood is used.
New filters are to be requested directly to the manufacturer. In order to replace the
activated charcoal filters, you should remove the anti-grease filters. Your are then to take
off the activated charcoal filters placed at the two ends of the aspirator. Turn the filters
until they unfasten from aspirator (Picture 3 - D).
Invert the operation in order to install the new charcoal filters.
In order to remove the remaining glue or any impurity, the cooker hood must be cleaned
immediately after installation and after having removed the protective film.
The cooker hood must be cleaned frequently both internally and externally (at least once a
month).
Do not let dirt gather on the inner and outer surfaces of the hood.
To clean the exterior of the hood do not use either acid or basic products, or abrasive
sponges.
Clean the hood with a sponge dampen in warm water and a little quantity of neutral
detergent (for example dishwasher detergent), in order to remove possible particles of
grease.
Rinse with a damp cloth, removing all the detergent carefully, following the satin finish
direction on the steel surface.
Drying is very important, especially in areas where water is particularly hard and leaves
limestone.
The hood features a LED light that, in addition to offering a good lighting and a significant
energy savings, are guaranteed to last on average 10 times more than traditional lights.
For replacement, contact the Assistance Service.
If the supply cord is damaged, it must be replaced by the service agent or similarly
qualified persons in order to avoid a hazard.
WARNINGS
The present instruction manual is an integral part of the appliance itself, therefore it must
be carefully kept and ALWAYS accompany it, even in case of its assignment to another
owner or user or in case the cooker hood is moved to another installation plant.
Any eventual adjustment to the electrical system, which may be necessary to install the
cooker hood, must be carried out only by competent people. Any repair carried out by no
competent people may cause damages. For any repair or needed technical action make
reference to a Technical Assistance Center, which is authorized to carry out the
replacement of the spare parts.
Always make sure that all the electrical parts (lights, exhaustion unit) are disconnected
when the appliance is not in use.
By storms take off the main switch of the house electrical system.
The using of the cooker hood must not be other than the use of exhausting units for
cooking damps on domestic kitchens. The manufacturer does not accept any liability for
damages caused by people, animals or things, by installation and maintenance mistakes
or by any illegitimate use.
Make sure that the voltage (V) and the frequency (Hz) ratings indicated on the plate
inside the cooker hood correspond to the ones available in the installation place.
We remind that the use of products functioning with electrical energy implies the
observance of some essential security rules, as follows:
This equipment is not intended for people (children included) with reduced mental
or motor capacities, with lack of experience or knowledge, unless they are
supervised or unless a person responsible for their security, gives them instructions
regarding the use of the equipment. Children must be supervised in order to be
sure that they do not play with the equipment.
Any cleaning action is forbidden if the appliance hasn’t been disconnected from the
main power supply and if the main switch of the house electrical system is not off. If
cleaning is not carried out according to these instructions, a fire may break out.
Do not pull, take off or twist the cable coming out from the appliance, even though
this has been disconnected from the main power supply.
Do not sprinkle or throw any water directly on the appliance.
Do not stick any sharp tool inside the exhausting holes and into the air discharge.
Do not take out the filters in order to reach the internal sides of the appliance in
case the main switch of the house electrical system is not off.
Do not singe or flambé directly underneath the cooker hood. Take particular care
when frying to ensure that the oil does not catch fire.
GB
Loading ...
Loading ...
Loading ...