Good Faith Guidelines for TV Installaons Above a Typical Gas Fireplace
Item Minimum Dimensions
A 2.5 inches
B
2 inches minimum to 3 inches maximum
C
COMBUSTIBLE: 23 inches:ECHEL36IN/STIN & 48IN/STIN
D
Wall Brkt + TV Thickness + 2.5 inches
B
B
A
Fireplace
TV
Mantel
A
C
Notes:
1. These are good faith recommended clearances only and not a guarantee of compliance with all TV
manufacturers’ maximum allowable operang temperatures.
2. Since every home has unique air flow characteriscs and maximum allowable operang temperatures
can vary from manufacturer to manufacturer and from model to model, actual TV temperatures should
be validated at the me of each installaon. TVs should not be used in situaons where the actual TV
temperature exceeds the manufacturers’ maximum allowable operang temperatures idenfied in the
TV’s technical specificaons. Contact the TV’s manufacturer directly if you cannot locate this
informaon or have quesons regar
ding the informaon.
3. Mantel height and depth must conform to mantle requirements specified in the fireplace installaon
manual.
4. “C” dimension taken from the top of the hood or fireplace opening.
5.
Suggesons on how to further reduce TV temperatures:
a. Increase “A” dimension.
b. Increase “C” dimension, however, increasing “B” dimension beyond maximum recommended
typically results in higher temperatures.
TV Wall
Bracket
D
Fireplace
C
TV on the wall
TV recessed into the wall
NON-COMBUSTIBLE 18 inches: ALL SIZES
COMBUSTIBLE: 27 inches: ECHEL60IN & ECHEL72IN
Figure 3.5. Good Faith TV Guidelines