6
ANTISCALE CARTRIDGE
To extend the life of the appliance and to avoid problems with lime scale, your steam generator is tted
with an anti-scale cartridge. The life of the anti-scale cartridge depends on the frequency of use and the
hardness of the water in your area. In a soft water area this should be about 100 uses. Do not put any
descaling products (including vinegar) into the reservoir. This can damage the appliance.
To replace the cartridge:
1. Switch o and unplug your steam generator
2. Allow your steam generator to cool down for at least 1 hour until the soleplate is cold.
3. Remove the water tank from the front of the unit.
4. Pull the anti scale cartridge vertically out of the water tank. Note that the cartridge may contain water
when it is removed (Fig A).
5. Fit the new cartridge and push it down rmly into the water tank.
6. Rell and ret the water tank.
7. Plug in your steam generator.
8. Once the appliance is ready, pull the steam trigger until the steam is being produced. This will prime
the system.
Important: Using the appliance without changing the cartridge can cause a reduction in the generated
steam output and damage the appliance. The guarantee will not cover damage caused to the appliance by
not changing the anti- scale cartridge when required.
REPLACEMENT ANTISCALE CARTRIDGES
1. Have the appliance Model Number to hand, as we won’t be able to help you without it. Its on the
rating plate (usually underneath the product).
2. Ring 0345 658 9700, or email service@russellhobbs.com, for prices, then purchase replacements using
VISA or MASTERCARD.
FILTER
We recommend that you remove and clean the lter every 6 uses depending on the water hardness in
your area. The warning light/reset button will ash to remind you that the lter needs cleaning. Doing this
will extend the life of the unit.
To remove the lter:
1. Unplug the appliance and let it cool down.
2.
C
Allow your steam generator to cool down for at least 1 hour until the soleplate is cold.
3. Remove the reservoir from the front of the unit. The lter is behind the reservoir.
4. Turn the lter anticlockwise and remove it (Fig B).
5. Rinse the lter under a tap.
6. Ret the lter and tighten it rmly.
7. Reset the reminder light.