Verona VDGCT212FSS Designer Series 12 Inch Gas Sealed Burner Cooktop

User Manual - Page 14

For VDGCT212FSS.

PDF File Manual, 20 pages, Read Online | Download pdf file

VDGCT212FSS photo
Loading ...
Loading ...
Loading ...
14
1
2
NATURAL GAS
REGULATION
LP/PROPANE
REGULATION
A
Fig.2.5
2
CONVERSION TO LP/PROPANEGAS (OR CONVERSION BACK TO THE
ORIGINAL GAS - NATURAL GAS)
Everycooktopisprovidedwithasetofinjectorsforthevarioustypesofgas.
Selecttheinjectorstobereplacedaccordingtothe“INJECTORSTABLE”.
Thenozzlediameters,expressedinhundredthsofamillimetre,aremarkedonthebodyofeachinjector.
CAUTION:Savetheoricesremovedfromtheapplianceforfutureuse.
SETTING THE PRESSURE REGULATOR
1. Unscrewtheregulatorcover.
2. Unscrewthe“A”component,reverseandscrewitaccordingtotheLP/PROPANE(orNATURALGAS)
regulation.
INJECTORS TABLE
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11”W.C.P.
NATURAL GAS
4”W.C.P.
BURNERS BTU/hr BTU/hr
Øinjector
[1/100mm]
Øinjector
[1/100mm]
Auxiliaryburner 4000 1000 58 92
Semirapidburner 7000 1500 76 123
Rapidburner 10000 2500 92 148
Dualburner(Mod.VDGCT530FSS)
16000(
1
)
15000(
2
)
5000
50(x1)(
3
)
73(x2)(
4
)
72(x1)(
3
)
135(x2)(
4
)
Dualburner(Mod.VDGCT536FSS)
18000(
1
)
16500(
2
)
5000
50(x1)(
3
)
76(x2)(
4
)
72(x1)(
3
)
143(x2)(
4
)
(
1
)PowercalculatedwithNaturalGas
(
2
)PowercalculatedwithLP/Propane
(
3
)Innercrown(“J2”ingure2.6b)
(
4
)Outercrown(“J3”ingure2.6b)
VDGCT212F..
VDGCT530FSSVDGCT424FSS VDGCT536FSS
Semirapid
Semirapid Semirapid
Semirapid
Semirapid Semirapid
Semirapid
Dual
Dual
Rapid
Rapid Rapid
Rapid
Auxiliary Auxiliary
Auxiliary
Loading ...