APPLIANCE ELECTRICAL CONNECTION
The electric connection must comply with the current legal standards and regulations.
Before making the connection, check that:
• The system electrical rating and the current outlet are adequate for the maximum power output of the
appliance (see the label applied to the bottom of the casing).
• The outlet or the system is equipped with an efficient ground connection in accordance with the
current legal standards and regulations. The manufacturer will not be responsible for the non-
compliance with these instructions.
• Range with Multifunction Electric oven :The power cord is supplied with a 15A plug, suitable for the
load indicated on the label and a standard 15A GPO.
• Range with Gas oven/Electric grill: The power cord is supplied with a 10A plug, suitable for the
load indicated on the label and a standard 10A GPO.
Fig. 16
• The power cord must be positioned so that a temperature of 75°C will not be reached at any point.
• Do not use reductions, adapters or splitters since they might cause false contacts and lead to
dangerous overheating.
When the connection is made directly to the electric network:
• Use a device that ensures disconnection from the mains in which the contacts are opened to a
distance that permits complete disconnection according to the conditions for over-voltage category III.
• The ground wire must not be interrupted by the circuit-breaker.
• As an alternative, the electric connection can also be protected by a high-sensitivity residual current
circuit- breaker but this may be subject to nuisance tripping due to residual humidity in heating
elements.
• It is highly recommended to attach the special green-yellow ground wire to an efficient ground system.
WARNING: If the power cord is replaced, the ground wire (yellow-green) connected to the terminal,
should be longer than the other wires by about 2 cm.
WARNING: if the supply cord is damaged, it must be replaced by the manufacturer or its service
agent or similarly qualified person in order to avoid a hazard.
TABLE N°3: TYPES OF POWER CORDS
Work surface
operation
Oven
operation
Cross section
230V ~
Only gas burner
Multifunction Electric oven 3x1,5mm²
Gas oven/Electric grill 3x1mm²
The appliance conforms to the regulation AS4551 regarding gas appliance for domestic use and
AS/NZS60335.26 regarding safety and CSPR 14 regarding electromagnetic compatibility.
Letter L (phase) =brown w i r e ;
Letter N (neutral) = blue w i r e ;
Ground symbol = green - yello w