20
OPERATION
The fireplace can be operated either by the switches located on the left bottom of the fireplace unit
or by supplied remot e cont rol.
Plug the fireplace into a 15 Amp wall socket .
M ANUAL OPERATION
1. The main power ON/ OFF swit ch in position O, the fireplace is OFF.
2. When main power ON/ OFF switch is at posit ion I, the fireplace is ready to use.
3. Press the
butt on repeat edly to set the heat er to desired heat set t ing. The heater indicator
LED will glow which show s the current heater settings.
a) RED 1500W HEAT OUTPUT
b) BLUE 750W HEAT OUTPUT
c) PURPLE AUTO M ODE
AUTO M ODE
Under this mode the heat er will automatically turn ON at high heat setting 1500W heat out put when
the room temperature drops below 22(72 ). When the room temperature is bet w een
22-25(72-77 ) the heat er out put will switch to low heat setting 750W. When the room
temperat ure goes above 25(77) the heat er will be turned off and the cycle will continue. The
LED indicator will be PURPLE in colour under this mode.
4. Flame effect: Press the button marked
to adjust the flame brightness. The flame bright ness
will cycle through Low -M edium-High -OFF.
5. M ood light effect: Press the button marked
to change the mood light colour.
NOTE: If operated at the Low heat setting, the fireplace will not provide as much heat out put as in
the High heat setting, however the low set t ing will not require as much elect rical pow er to operate.
To avoid overloading a circuit, do not plug the fireplace into a circuit that already has ot her
appliances working. When the fireplace is not in use swit ch off and unplug.
SAFETY CUT-OFF
l This appliance is fit ted wit h a safet y cut -off which will operate if the fireplace overheat s (eg. Due
to blocked air vent s). For safet y reasons, the fireplace will NOT aut omatically reset.
l To reset the appliance, disconnect the appliance from the main supply for at least 10 minut es.
Reconnect the supply to the main and switch on the appliance.