Performance Data Sheet
SmartWater Filtration System-GE ® HSWF Cartridge
This system has been tested and certified in filter model GEMSWFaccording to NSF/ANSIStandards 42 and 53 for reduction of the substunces listed below.
The concentration of the indicated substances in water entering the system was reduced to o concentration less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSIStandards 42 and 55.* (Safety factors built in for unmetered usage.}
Standard No. 42: Aesthetic effects
Parameter ' USEPAMCL
Effluent' % Reduction I
Concentration Average ' Maximum ..... Average ' Maximum Min. Required Reduction
2.0mg/L ± 10% 0.06 mg/L 0.10 mg/L 97% 9.1% ->50%
at least 10,000particles/ 408,333 670,000 95.5% 89.4% > 85%
mL
Standard No. 53: Hearth effects
.......... Effluent % Redaction ..........
Parameter
USEPAMCL Concentration Average Maximum
1 NTU.... 11_+1 NTU.... 0.38 NTU 0.S NTU
99.95% Reduction Minimum 50,000 L < 1 #/L 4 #/L
0.010 mg/L 0.15 mg/L ± 10% < 1ppb < 1 ppb
0.010 mg/L 0.1S mg/L ± 10% 3.1ppb 9.0 ppb
0.002 mg/L 0.006 mg/L ± 10% 0.34 ppb 0.7 ppb
0.002 mg/L 0.006 mg/L ± 10% 0.66 ppb 1.5ppb
0.0002 mg/L 0.002 mg/L _+10% < 0.02 ppb < 0.02 ppb
0.003 mg/L 0.009 mg/L ± 10% <O.Sppb < O.OSppb
0.070 mg/L 0210 my/L± 10% 7.7ppb 35 ppb
0.003 mg/L 0.015 mg/L ± 10% < 1 ppb < 1 ppb
0.005 mg/L 0.015 mg/L ± 10% < 0.S ppb < 0.5 ppb
0.040 mg/L 0.080 mg/L ± 10% < 1 ppb i ppb
0.075 mg/L 0.225 mg/L _+10% < 0.5 ppb < 0.5 ppb
99% Reduction 107 to 10 8fibers/L; < 0.17 MF/L <0.17 MF/L
fibers > 10pro in length
*Testedusing pressureof 60 psig;pH of 7.5± 0.5;temp of 680± 5%120° ±2.5°C}.
**Measurement in Partides/mL Particles used were 0.5-1microns.
***Based onthe useof Cryptosporidium parvum oocysts.
.... NTU=NephelometricTurbidity Units
Capacity300 gallons (i,135 liters).Contaminant reduction determined by NSFtesting.
Average
96.5%
> 99.99%
99.3%
98.0%
94.0%
88.4%
> 99.0%
> 93.9%
96.0%
>92.9%
>96.8%
> 98.7%
>99.7%
> 99%
Maximum
95.4%
> 99.99%
99.3%
95,5%
89.6%
73.7%
> 99.0%
> 94.3%
82.0%
> 92.9%
> 97.0%
>98.7%
> 99.8%
>99%
ProductWater
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 rng/L
0.040 mg/L
0.075 mg/L
99% Reduction
Application Guidelines/Water Supply Parameters
ServiceFlow Water Pressure
WaterSupply Water Temperature
It is essentialthat the manufacturer'srecommendedinstallation,maintenanceand filter replacementrequirementsbe carriedout for the productto perform asadvertised.
See insert for Warranty information.
Operating Specifications
®Pressure requirement: 40-120 psi (2.8-8.2 bar), non-shock
Temperature: 33-100°F (0.6-38°C)
Flow rote: 0.9 gpm (3.14 Ipm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 4-1/2 gallons (about five minutes} to purge
trapped air.
Replace cartridge when flow becomes too slow.
Protect from freezing by removing filter cartridge when temperatures are
expected to drop below 40°F (4.4°C). Do not install systems in areas where
ambient ternperatures may go above 100% or below 40°E Do not install
on a hot water supply.
SpecialNotices
Installation instructions ore included with the product when shipped.
, This drinking water system must be maintained according to manufacturer's
instructions, including replacement of filter curtridges.
Do not use with water that is microbio)ogically unsafe or of unknown quality with-
out adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected wuter that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water
treatment system are not necessarily in your water.
, Check for compliunce with the applicable state and local tows and regututions.
. Note that while the testing wus performed under standard laboratory conditions,
actual performance may vary. Systems must be instulled and operated in
accordance with manufacturer's recommended procedures and guidelines.
Installation and use MUST comply with all state and local plumbing codes. Do not
instull if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPa), you should install a pressuredimiting valve. Contact a plumbing
professionul if you ore uncertuin how to check your water pressure.
- Do not install where water hammer conditions may occur. If water hummer
conditions exist you must install a water hammer arresten Contact a plumbing
professional if you are uncertain how to check for this condition.
. Where o backflow prevention device is installed on a water system, u device for
controlling pressure due to thermal expansion must be installed.
For conditions of use, heulth claims certified by the California Department of Public
Health, and rep)ocements, see performance data sheet. California Deportment
of Public Heulth Certification #06-1834. The contaminants or other substances
removed or reduced by this water filter are not necessarily in oil users' woten
Tested and Certified by NSF International against ANSI/NSF Standards 42 and 53 in model GE MSWF for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical
- Chlorine Taste and Odor
Mechanical Filtration
- Particulate Reduction, Class I
GE
Appliances
Appliance Pork
Louisville, KY 40225
geapplianceparts.com
Standard No. 53: Health Effects
,, Chemical Reduction
- Atrazine Reduction
- Endrin Reduction
- Benzene and Corbofuron Reduction
- 1,4 Dichlorobenzene and
2,4-D Reduction
- Lead and Lindane Reduction
- Mercury and Toxophene Reduction
Mechanical Filtration
- Cyst and Asbestos Reduction(_
REPLACEMENT ELEMENT
EPA#10350-MN-005
© 2010 General Electric Company PC61577C