7
Operation
B. “-- “ Button
Pressing this button toggles se-
quentially through the three levels
of the replace: ame only; to
ame and low heat; to ame and
high heat.
!
NOTE: After the unit is
switched from ame and high
heat to another function there
is a 30 second fan delay,
where the fan will continue
running before turning off.
C. “O” Button
Pressing this button at any time
will shut the unit off.
D. 3-Position Switch
Switches the operation of the
replace between the different
modes of the replace:
OFF (center): Makes the unit
inoperable.
MANUAL (top): All functions
of the replace are controlled
by the On and Off buttons as
described above (B, C).
REMOTE (bottom): All func-
tions of the replace are con-
trolled by the Remote Control.
E. LED Indicators
Depicts which of the three levels
the replace is currently operating
at: Level 1 , Level 2 or Level
3 .
F. Voltage Selector Switch
Needs to be set to reect the in-
coming voltage to the unit - 115V
or 230V.
!
NOTE: The heater may emit
a slight, harmless odor when rst
used. This odor is a normal con-
dition caused by initial heating of
internal heater parts and will not
occur again.
Resetting the Temperature
Cutoff Switch
Should the heater overheat, an
automatic cut out will turn the
replace off and it will not come
back on without being reset. It
can be reset by switching the On/
Off Switch to Off and waiting ten
minutes before switching the unit
back on.
CAUTION: If you need to
continuously reset the heater,
disconnect power and call
Dimplex customer service at
1-888-DIMPLEX
(1-888-346-7539).
Remote Control
The replace is supplied with a
radio frequency remote control.