12/03/2021 Page 43 of 56
SPRAY BAR
SPRAY BAR
WATER
SHUTTERS
WATER
SHUTTERS
ICE GUIDE
ICE GUIDE
PUMP CLEAN-OUT CAP
WATER SHUTTER
The water shutter hangs in front of the spray bar and
ice guide. It prevents spraying water from escaping the
evaporator compartment.
REMOVAL
Lift the shutter rod's ends from the recesses in the
sidewall.
INSTALLATION
Insert the shutter rod's ends into the recesses in the
sidewall. To be correctly installed, the water shutter
must–
Hang from a shutter rod fully seated in the recessed
end supports.
Conceal the ice guide finger holes.
INCORRECT.
Ice guide finger holes are visible.
CORRECT.
Ice guide finger holes are hidden; ice guide slotted holes are
visible.