Instructions for Converting Rangetop to Operate on Liquefied Petroleum Gas
6. Reconnect Gas and Electrical Supply to
Rangetop
Leak testing of the appliance shall be
conducted according to the installation
instructions provided with the rangetop.
Checking for Manifold Gas Pressure
If it is necessary to check the manifold
gas pressure, remove the burner cap,
inner ring, outer burner head and burner
base of the right front top burner and
connect a manometer (water gauge) or
other pressure test device to the burner
orifice. Use a rubber hose with inside
diameter of approximately ¼ and hold
the end of the tube tight
over the orifice.
Turn the gas valve on. For a more
accurate pressure check, have at least
two (2) other top burners burning. Be
sure that the gas supply (inlet) pressure is
at least one inch above the specified
mmaanniiffoolldd pprreessssuurree.. TThhee ggaass ssuuppppllyy
pressure should never be over 14” water
column. When properly adjusted the
manifold water column pressure is 10”
for LP/Propane gas or 5” for Natural
Gas
Do not use a flame to check for gas
leaks
a. Disconnect the rangetop and its
individual shut -off valve from the gas
supply piping system during any pressure
of that system at test pressures greater
than 14” of water column pressure
(approximately ½ psig)
b. The appliance must be isolated from
the gas supply piping system by closing
its individual manual shut -off valve
during any pressure testing of the supply
system at test pressure equal to or less
than 14” water column pressure
(approximately ½ psig)
7. Installation of New LP / Propane
Rating / Serial Plate
Record the model and serial number
on the LP / Propane Rating serial
plate provided in this kit. The
information can be obtained from the
existing Rating / Serial plate. Place
the new plate as close as possible to
the existing Rating / Serial plate on
the rangetop.