en Installation and connection
8
Converting the cooktop from Nat. Gas to
Propane
All work involved in installation, setting and adaptation
to a different gas type must be carried out by
authorised personnel from our Service Centre and must
comply with current regulations and the conditions laid
down by the local gas company.
Before conversion the cooktop must be disconnected
from the electricity and gas valves must be turned to the
OFF position.
Important: After finishing, stick the sticker, indicating
the new gas type, close to the specifications plate.
Replacing the injectors
Request change-over injectors from our customer
service deparment (refer injector chart below for sizes).
Replacing the nozzles of rapid, standard and
economy burners
1. Remove the pan supports, burner caps and
diffusers.
2. Change the nozzles using the spanner (code
424699) provided by our Technical Assistance
Service, taking special care to ensure that the nozzle
does not fall when it is removed from or fitted to the
burner.
Ensure that it is completely tightened in order to
guarantee the seal.
Primary air adjustment is not necessary with these
burners.
Replacing the nozzles on dual-flame burners
Before you can replace the nozzles, you will need to
remove the glass plate with the cut-out profiles for the
appliance. The glass plate with the cut-out profiles is
connected to the rest of the hob by means of a clip
system.
Removing the glass plate with the cut-out profiles:
1. Remove all wire racks, burner caps, burner rings,
control elements and burner cups.
2. Undo the screws on the burners.
3. To do this, use the removal lever, which is available
from our after-sales service (code 483196). Use the
lever to release the front clip fastener at the point
shown in figure, depending on the hob model.
Caution!
Only use the lever on the edges of the glass that
have a cut-out profile or a frame.
Natural Gas Propane
Hourly Gas
Consumption
(MJ)
Injector
mark
Hourly Gas
Consumption
(MJ)
Injector
mark
Economy
burner
4,8 97 3,5 53
Standard-
output
burner
8.1 130 6 70
High-output
burner
11.6 157 8.5 83
Wok burner
(inner)
22 65 20 47
Wok burner
(outer)
215 115
Distance Z 11 11
