Loading ...
Loading ...
Loading ...
askona.com/specs
|
7
Electrical
The electrical supply should be located in an adjacent
cabinet. If the supply cannot be located in an adjacent
cabinet, it must be located within the shaded area shown in
the illustration below. A separate circuit, servicing only this
appliance is required.
IMPORTANT NOTE: For the outdoor model, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock. A GFCI is not recommended for use with
other models and may cause interruption of operation.
Installation must comply with all applicable electrical codes.
ELECTRICAL REQUIREMENTS
Electrical Supply 115 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
5
3
/8"
(137)
OPENING
WIDTH
AREA EXTENDS 2" (51)
FORWARD ON FLOOR
Electrical supply location.
Plumbing
The water supply and drain should be located in an adjacent
cabinet. If they cannot be located in an adjacent cabinet,
they must be located within the shaded area shown in the
illustration below. The water supply line should be con-
nected to a hot or cold house supply with an easily acces-
sible shut-off valve between the supply and the unit.
Installation must comply with all applicable plumbing codes.
PLUMBING REQUIREMENTS
Water Connection 6' (1.8 m) PEX tubing with
3
/8" NPT female connection
Pressure 4.2–140 psi
(.3–9.7 bar)
ASKO DISHWASHERS
5
3
/8"
(137)
OPENING
WIDTH
AREA EXTENDS 2" (51)
FORWARD ON FLOOR
Water supply and drain location.
Loading ...
Loading ...
Loading ...