AGA AMCHD44SKY

User Manual - Page 12

For AMCHD44SKY.

PDF File Manual, 15 pages, Read Online | Download pdf file

AMCHD44SKY photo
Loading ...
Loading ...
Loading ...
EN
1
12
ELECTRICAL CONNECTION
Remove the cover from the Field Wiring Com-
partment with a Phillips screwdriver.
Feed the Power Supply Cable through the electrical
knockout. Connect the Power Supply Cable to the
rangehood cable. Attach the Power Supply Cable
grounding lead to the green screw provided. Attach
the White lead of the power supply to the White
lead of the rangehood with a twist-on type wire
connector. Attach the Black lead of the power sup-
ply to the Black lead of the rangehood with a twist-
on type wire connector.
• Replace the cover.
For the 36"
Knockout is located in the junction box on the lef
t
side of the hood facing the front approx. 9-3/8" from
the left to the right and 3-3/8" up from the bottom o
f
the hood.
For the 44" model
Knockout is located in the junction box on the Left
side of the hood facing the front approx. 13-3/8" from
the left to the right and 3-3/8" up from the bottom o
f
hood.
Chimney assembly
Upper exhaust Chimney
Slightly widen the two sides of the upper chimney
and hook them behind the brackets 7.2.1, making
sure that they are well seated.
Secure the sides to the brackets using the 4 screws
12c supplied.
Lower exhaust Chimney
Slightly widen the two sides of the chimney and
hook them between the upper chimney and the
wall, making sure that they are well seated.
Fix the lower part laterally to the hood body using
the 2 screws 12c supplied.
12c
12c
12c
2.2
2.1
2
Power supply cable
Green
Ground
screw
Ground wire
Loading ...
Loading ...
Loading ...