6. Troubleshooting
The Unit is Not Turning On
Check whether the unit has been turned on.
Check the power supply (try a dierent power source/vehicle/socket).
Check whether the plug and the socket have a good connection.
Check whether the circuit breaker has tripped (located on the back of the fridge in the
compressor bay).
Low Refrigeration Performance
Too much product been placed inside the unit.
There is too much warm product inside the unit .
The door is unlatched / or open.
The seal is broken.
Problems arising from poor ventilation (allow at least 50mm of space around the fridge,
see diagram on pages 9 and 10).
The ambient temperature is too high.
The temperature setting is too high.
Yellow Fault Light Flashing (Located on the Control Panel)
1 Flash every 4 seconds: Low Voltage
Try on dierent power source (vehicle or 240V AC power). If changing power source fixed
issue, then possible issue with original power source.
Ensure cabling between fridge and battery is at least 4mm
2
, if the distance is more than 2
metres then use at least 6mm
2
cable.
2 Flashes every 4 seconds: Fan Issue
Fan is drawing too many amps (over 0.5 amps), replace fan.
3 Flash every 4 seconds: Compressor Start Issue
Unplug cable and allow unit to rest for 10 minutes.
Try on dierent power source (vehicle or 240V AC power).
Electronic box fault.
Compressor fault.