Instructions for the Installer
17
Undo the screw D and push the air regulator C fully down. Use a
spanner to remove the nozzles B and fit those of suitable type
following the instructions given in the tables for bottled gas ULPG 2.75
kPa. The nozzle must not be tightened to a torque of over 3 Nm.
Burner
ULPG 2.75 kPa
Nominal gas consumption
(MJ/h)
Injector
(mm)
Auxiliary
4.8
0.60
Semi rapid
5.9
0.65
Rapid
8.6
0.78
Rapid Large
9.5
0.85
Fish Pan
9.5
0.78
Wok
15.0
1.05
6.4 Regulation for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for ULPG, perform the same operations described in
paragraph “6.3 Adjustment for ULPG”, but refer to the following table for
the proper injectors.
Burner
NG 1.0 kPa
Nominal gas consumption
(MJ/h)
Injector
(mm)
Auxiliary
4.8
0.98
Semi rapid
5.9
1.10
Rapid
8.6
1.25
Rapid Large
11.4
1.50
Fish Pan
11.4
1.50
Wok
15.0
1.70