Kenmore 79681582410 steam dryer

Use & Care Guide - Page 10

For 79681582410. Also, The document are for others Kenmore models: 796.8158*, 796.9158*

PDF File Manual, 72 pages, Read Online | Download pdf file

79681582410 photo
Loading ...
Loading ...
Loading ...
CONNECTING GAS DRYERS
GAS REQUIREMENTS (GAS MODELS ONLY)
A WARN ING: Toreducetheriskoffire,
electric shcck, or injury to persons when using this
appliance, follow basic precautions, including
the foltowirg:
* Gas supply requirements: As shipped from the
factory, this dryer is configured for use with natural
gas (NG). it car= be converted for use with propane
(LP) gas. Gas pressure must not exceed 8 inches
wa_er column for (biG), or 13 inches water column for
(LP).
* A qualified service or gas company technician must
connect the dryer to the gas service. Failure to follow
these instructionscan result in fire, explosion, or death.
=isolate the dryer from the gas supply system by
closing its individual manual shutoff valve dLmrlngany
pressure testing of |he gas supply. Faiture to do sa can
result in fire, explosion, or death.
Supply llne requirements: Your laundry room must
have a rigid gas supply llne to your dryer, in the
United States, an indivldual manual shutoff valve
MUST be installed within o$ least 6 ft. (1.8 m) of the
dryer, in accordance with the National Fuel Gas Code
ANSI Z223.1 or Canadian gas installation code CSA
B149.1. A Vs inch NPT pipe plug must be installed.
Failure to do so can result in fire, explosion, or death.
"If using a rigid pipe, the rigid pipe should be ½ inch
IPS. if acceptable under |ocal codes and ordinances
and when acceptable to your gas supplier, 3/_ inch
approved tubing may be used where lengths ore less
than 20 ft. (6.1 m). Larger tubing should be used for
lengths in excess of 20 ft. (6.1 m). Failure to do so can
result in fire, explosion, or death.
* Connect the dryer to the type of gas shown on
the nameplate. Failure to do so can result in fire,
explosion, or death.
To prevent contamination of the gas valve, purge the
gas supply of air and sediment before connecting
the gas supply to the dryer. Before tightening the
€onnection beh_,een the gas supply and the dryer,
purge remaining air until the odor of gas is detected.
Failure to do so can result in fire, explosion, or death.
DO NOT use an open flame to inspect for gas leaks.
Use a noncorrosive leak detection fiuid_ Failure to do
so can result in fire, explosion, or death.
- Use only a new AGA- or CSA-cerfified gas supply
line with flexible stainless steel connectors. Failure to
do so can result in fire, explosion, or death.
* Securely tighten all gas connections. Failure to do so
can result in fire, explosion, or death.
"Use TeRon tape or a plpe-jolnt compound that is
insoluble in propane (LP) gas on all pipe threads.
Failure to do so can result in fire, explosion,
or death.
oDO NOT attempt any disassembly of the dryer;
disassembly requires the affentlon and tools of
an au_ho_zed and qualified service technician or
company. Faitureto follow this warning can result in fire,
explosion, or death.
ELECTRICAL REQUIREMENTS FOR
GAS MODELS ONLY
Do not, under any circumstances, c_ or remove the
third (ground) prong from the power cord. Failure
ta fallow this warning can result in fire, explosion, or
death.
"For personal safety, this dryer must be properly
grounded. Failure to follow this warning can result in
fire, explo_ion, or death.
The power cord of this dryer is equipped with
a 3-prong (grounding) plug which mates with a
standard 3-prong (grounding) wall outlet to minimize
the possibility of electric shack hazard from this
appllance. Failure to follow this warning can result in
fire, explosion0or death.
* Thls dryer must be plugged into a |20-VAt, 60-Hz.
grounded outlet protected by a |5-ampere fuse or
circuit breaker. Failure to follow this warning can result
in fire, explosion, or death.
Where a standard 2-prong wall outlet is encountered,
it is your personal responsibility and obligation to
have it replaced with a properly grounded 3-prong
wall outlet. Failure to follow this warning can result in
fire, explosion, or death.
3=prong
grounding
type wall
grounding
plug
Ensure proper
ground exists
before use.
10
Loading ...
Loading ...
Loading ...