CLEANING & MAINTENANCE
cleaning & maintenance
nuwavenow.com
Filter Maintenance Indicator
The FILTER 2 and FILTER 4 lights will turn green in about 3 months to
alert you that the Bio-Guard
®
lters SHOULD be cleaned to maintain
optimal performance (NuWave Recommendation). When either light turns
red (after about 6 months), that Bio-Guard
®
lter MUST be cleaned. Once
cleaned, press and hold down TIMER for 2 seconds until a beep is heard
to reset the Clean Filter 2 Indicator. To reset the Clean Filter 4 light, hold
the TURBO button for 2 seconds until a beep is heard. Once the Clean
Filter lights are reset, they will go out.
Cleaning the Dust Sensor
The Dust Sensor is located on the side of the unit.
1. Open the Dust Sensor Cover.
2. Using a dry cotton swab or small, soft brush, gently remove any dirt or
dust from the Sensor.
3. For more buildup on the Sensor, wipe it with a slightly wet cotton swab.
4. Remove any moisture with a dry cotton swab.
5. The Sensor requires regular cleaning (approx. every 3 months) for the
unit to operate efciently.
6. If the OxyPure
®
is set up in an area with high dust accumulation, more
frequent cleaning of the Sensor is needed.
7. Do not use the cotton swab on any part or area other than the Sensor.
Do not immerse the OxyPure in water. Clean the outside of the unit with
a damp sponge or cloth and wipe it dry. Make sure all parts and covers
are securely attached. Do not dry the lters with a hot blow dryer.
Changing and Cleaning the Filters
The lters need to be cleaned on schedule to help the unit maintain
optimum performance.
1. Remove the Filter Access Panel in the rear of the OxyPure
®
using its
built-in handle.
2. Carefully slide out the lters that need cleaning. Do not shake them.
3. Immerse the Stainless-Steel prelter and Bio-Guard
®
lters in water.
DO NOT get the Ozone Emission Removal Filter wet.
4. Clean the lters as directed. DO NOT use paper towels.
5. Always allow the washable lters to dry completely, out of direct sunlight,
before you reinstall them. Never place a wet lter into the OxyPure.
6. Reattach and close the Filter Access Panel. If the panel is not properly
closed, the POWER button will blink red and the unit will not power on.