Accucold ARS8PVDL2B 24 Inch White Counter Depth All Refrigerator, in White

User Manual - Page 14

For ARS8PVDL2B.

PDF File Manual, 20 pages, Read Online | Download pdf file

ARS8PVDL2B photo
Loading ...
Loading ...
Loading ...
14
When the electric supply is off, flash and display EEL and alarm. When setting do1 is set at “00, unit will
not alarm when door is open. When setting do1 is set at “0, once unit reaches the delay time, it wil
flash and display dr alarm, press random button to cancel.
If setting C7 is set to “0, then the units relay does not alarm when power is off.
If setting C8 is set to “0, then after alarm is canceled, the alarm relay does not close. I
f C9 is set to “0, then after the alarm cancel button is pushed, the buzzer does not restart.
If setting other numbers, then after reaching delay time, buzzer sounds one more time. (Under the
condition of alarm not terminating)
Abnormal work mode: When air sensor is short-circuited or high temperature over limit (
66/151), "1H" is displayed; when air sensor is open-circuited or low temperature over limit (<-
40/) "1L" is displayed. Compressor will enter the force running mode, according to C10, C11 set
parameters running in sequence.
When product sensor is short-circuited, open-circuited or over limit (66/151), alternate display
2H and air temperature, the product temperature sensor open-circuited or low temperature over limit (
<-40/), alternate display 2L and air temperature.
Instrument running alarm indication list
Alarm type
Compressor running
Display flash
Refrigerator high temp. alarm
Compressor on
H1 delay alarm
Refrigerator low temp. alarm
Compressor off
L0 delay alarm
Air temp. sensor short-circuited
Press C10,C11to run the comp.
1H intime alarm
Air temp. sensor open-circuited
Press C10,C11to run the comp.
1L intime alarm
Product temp. sensor short-circuited
2H intime alarm
Product temp. sensor open-circuited
2L intime alarm
Product temperature high temp.
Limit alarm
H2 delay alarm
Product temperature low temp.
Limit alarm
L2 delay alarm
Electric supply off alarm
EEL flash and alarm in time
Door open delay alarm
Dr flash and delay alarm
When the door is open, the light switch can turn the light on and off.