Check agitator shield
Because your cleaner picks up so well,
we strongly recommend you check for
debris accumulation under the agitator
shield each time you clean the filters.
Removing debris under the shield will
help maintain your cleaner's excellent
pick up and suction. Remove debris as
follows:
1. Disconnect cleaner from electrical
outlet.
2. Check for dirt accumulation by
removing bottom plate (Fig. 3-17),
removing agitator (Fig. 3-18), and lifting
agitator shield (Fig. 3-20).
3. Remove any debris and replace
shield, agitator and bottom plate (Figs.
3-20 to 3-22).
Headlight replacement
What to buy
This cleaner uses a 12 volt, wedge base
type 912 bulb, HOOVER part No.
27313101.
Removing lens
Disconnect cleaner from electrical
outlet.
Using a screwdriver, remove tile two
screws as shown and lift off lens.
Installing bulb
Pull old bulb straight out of socket.
Push new bulb straight into socket until
locked in place
Excessive force is not required.
Replacing lens
Reposition lens and secure with the two
screws.
Belt replacement
The belt on your HOOVER cleaner
causes the agitator to rotate and is
important for the effective operation of
the cleaner. The belt is located under
the bottom plate of the cleaner and
should be checked from time to time
to be sure it is in good condition.
When to replace
Disconnect cleaner from electrical
outlet.
To check belt, remove bottom plate as
shown in "How to replace." Replace
belt if it is stretched, cut or broken.
What to buy
To assure effective operation, use only
genuine HOOVER belts with your
cleaner. When purchasing a new belt,
ask for HOOVER part No. 38528033.
How to replace
Disconnect cleaner from electrical
outlet.
Place handle in low position and turn
cleaner over so bottom side is up.
Remove the 4 screws as shown with a
Phillips screw driver.
Lift off bottom plate (A).
Removing belt
Remove agitator brush roll and used
belt.
Discard used belt.