Miele 11791750 HR 1956-3 LP DF GD M Touch 48" Clean Touch Steel Liquid Propane Dual Fuel Range With Griddle HR19563DFGDLP

User Manual - Page 108

For 11791750.

PDF File Manual, 124 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Gas connection
*INSTALLATION*
108
The installation must comply with
local regulations or, if there are no
local regulations, the National Fuel
Gas Code, ANSIZ223.1/NFPA54.
The gas pressure may not
undershoot or exceed certain values.
Make sure that the maximum gas
pressure upstream of the gas
pressure controller does not amount
to more than 1/2psi (3.5kPA) for
natural gas NG and liquid propane
LP.
Make sure that the minimum gas
pressure amounts to a 6" water head
in the case of natural gas and a 11"
water head in the case of propane
gas.
1/2" NPT