Cabinet Layout
All maximum and minimum dimensions and clearances
shown in the diagrams below must be maintained for safe
operation.
Check the location where the range is to be installed. It
should be placed away from drafts that may be caused by
doors, windows and heating and air conditioning outlets.
To reduce accumulated smoke in the room, Dacor strongly
recommends installation with a range hood or approved
downdraft.
To reduce the risk of fire or personal injury from reaching over
a hot appliance, avoid cabinet installations directly above the
range. If cabinet storage is to be provided, the risk can be
reduced by installing a range hood that projects horizontally a
minimum of 5 inches beyond the bottom of the cabinets.
The range may be installed flush to the rear wall. Dacor
strongly recommends installing a non-combustible material
on the rear wall above the range and up to the hood or
installation of a backguard. It is not necessary to install non-
combustible materials behind the range below the countertop
height. Any openings in the wall behind the appliance or in
the floor underneath it must be sealed.
Gas and Electrical Service
The shaded area shown below denotes the location of the
gas inlet and the electrical outlet. This is the recommended
location. For replacement purposes, the location of the
existing utilities may be utilized provided they do not interfere
with the sides or rear of the range. Check local building codes
for permissible gas valve locations.
An external manual shut-off valve must be installed between
the gas inlet and the range for the purpose of turning on or
shutting off gas to the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the electrical outlet, when the range is in place.
The gas supply piping and shut-off valve, and the electrical
outlet must be located so they do not interfere with the range
when it is installed.
The electrical outlet and gas shut off valve must be located
so that the range can be pulled out for service while the
appliance remains connected.
Planning the Installation
APPROVED DOWNDRAFT
Range Model RNRP30G
Downdraft ERV3015
Trim Kit
ATKERV-RP30 (Required when
using the 3-in backguard)
IMPORTANT: Read the ERV3015 Installation Instructions
for duct and electrical installation requirements. Use only
the Dacor downdraft model(s) specified above.
ATKERV-RP30 Trim Kit is required.
A downdraft with a 3-inch backguard requires adding
the ATKERV-RP30 trim kit to create a uniform unit.
Install ATKERV-RP30 onto the back of the range.
The ATKERV-RV30 trim piece on the back of the range
will cover the downdraft chassis.