OPERATIONS MANUAL
BOTTLE, KEG & BACK BAR COOLERS, GLASS & PLATE CHILLERS
CAUTION: IF UNIT IS UNPLUGGED OR DISCONNECTED
FOR ANY REASON, ALLOW 5-6 MINUTES BEFORE
TURNING THE UNIT BACK ON TO ALLOW THE SYSTEM
TO EQUALIZE. DISREGARDING THIS PROCEDURE
COULD CAUSE AN OVERLOAD AND PREVENT THE UNIT
FROM OPERATING.
SPECIAL VOLTAGE CONNECTIONS
When models are ordered from the factory with special, optional
voltages, connections should be made as required on the electri-
cal wiring diagram provided on the inside compressor compart-
ment rear next to the electrical console box.
START-UP CHECKLIST
After your unit has been installed and electrically connected in
accordance with this manual, please take time to check the fol-
lowing before loading product, to assure trouble free operation:
Sufficient clearance provided (see “Ventilation”)
Seperate power supply with correct voltage
(see “Electrical Connections”)
Cabinet level and sealed (see “Mounting and Leveling”)
Doors close and seal properly (see “Door Adjustment”)
Correct cabinet temperature
(see “System and Adjustment”)
Refrigeration lines free of kinks and vibration
(see “Refrigeration System”)
Condenser and evaporator fans rotate freely
(see “Refrigeration System”)
All packaging discarded and cabinet cleaned
(see “Periodic Cleaning”)
BBC/CGC: Shelves installed correctly (see “Shelving”)
CBC: Dividers installed with springs (see “Wire Dividers”)
KC: Towers and kegs correct (see “Direct Draw Set-Up”)
The system should run smoothly and quietly in accordance
with generally accepted commercial standards. If any unusual
noises are heard, turn the unit off immediately and check for any
obstructions of the condenser or evaporator fans. Fan motors,
fan blades, or fan housings can be jarred out of position through
rough handling in transit or during installation.
GFI/GFCI RECEPTACLES
Ground-Fault Circuit Interrupter (GFCI or GFI) devices are not
recommended for most commercial refrigerators and freezers,
since nuisance trips may occur, typically due to moisture. This
can cause temporary loss of power, which may result in high
storage temperatures and potentially unsafe food product.
Building codes in some areas may require certain 115 volt
receptacles to be protected by a GFI If you need to connect your
equipment to a protected circuit, a properly sized, commercial
grade GFI circuit breaker should be used on a separate, isolated
power supply. Or a qualified electrician may be able to hard wire
your equipment, eliminating the need for a GFI device. Contact
Continental’s Service Department before making any modifica-
tions to your cabinet, to avoid loss of warranty.
NOTE: GFI RECEPTACLES ARE NOT RECOMMENDED,
PRODUCT LOSS OR SERVICE PROBLEMS RESULTING
FROM NUISANCE TRIPS, CONNECTION TO A DEFECTIVE
OR IMPROPER POWER SUPPLY, AND UNAUTHORIZED
MODIFICATIONS TO YOUR EQUIPMENT CAN CAUSE A
HAZARD AND WILL VOID FACTORY WARRANTY.
115 VOLT, 60 HZ, 1 PHASE CONNECTION
All 115 volt models are provided with a factory
installed, UL approved 15-amp power cord and
NEMA 5-15P plug, or a 20-amp power cord and
NEMA 5-20P plug. To insure proper operation,
this equipment must be plugged into a NEMA
compatible, grounded receptacle that can sup-
ply the full voltage and amperage stated on the
serial plate (see Figure 1).
IMPORTANT NOTE: A SEPARATE, ISOLATED, PROPERLY
SIZED POWER SUPPLY MUST BE PROVIDED. GFCI
DEVICES AND/OR EXTENSION CORDS SHOULD NOT
BE USED. PRODUCT LOSS, AS WELL AS PROBLEMS
RESULTING FROM NUISANCE TRIPS OR HIGH/LOW
VOLTAGE, ARE NOT COVERED UNDER WARRANTY.
09/03/10