16
F. Molded Brick Panels
Frequency: After each ash removal
By: Homeowner
The panels should be replaced if
Cracks exceed ¼ inch (6 mm) in width
Metal is exposed behind a panel
Large pieces of panel fall out
Inspect grate for:
Warping or sagging 1-1/2 in. (38 mm) or more
Broken welds
Burn-through of grate bars
For safe operation, replace only with the approved grate
from Hearth & Home Technologies.
C. Grate
Frequency: After each ash removal
By: Homeowner
E. Ash Removal
Frequency: As necessary
By: Homeowner
Tools Needed: Covered metal container, metal
shovel, replace broom
WARNING! Risk of Fire! DO NOT remove ashes until
thereisoutandthereplaceiscold.
Ashes should be placed in metal container with tight
tting lid.
The closed container of ashes should be placed
on a noncombustible oor or on the ground, well
away from all combustible materials, pending nal
disposal.
If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be retained
in the closed container until all cinders have
thoroughly cooled.
D. Glass Cleaning
Frequency: As necessary
By: Homeowner
Tools Needed: Vinegar or glass cleaner, soft towel
Clean glass with a non-abrasive glass cleaner. Use a
damp cloth dipped in wood ashes or a commercially
available oven cleaner. Remove any oven cleaner
residue with a glass cleaner or soap and water.
Majestic Ashland Series • ASH42 OWNERS MANUAL • 4059-916 • Rev B • 03/17/16