3) Electrical Data
Electrical Data
Model
Voltage (V)
LRA - Comp. (A)
Cooling Current (A)
MIN. Ckt. Amps (A)
Power Connection
230/208 230/208 230/208
21 21 21
4.4/4.9 4.4/4.9 4.4/4.9
15 20 30
HARD WIRED
/
230/208 230/208 230/208
24.0 24.0 24.0
5.5/6.1 5.5/6.1 5.5/6.1
15 20 30
HARD WIRED
230/208 230/208 230/208
47 47 47
9.2/10.2 9.2/10.2 9.2/10.2
15 20 30
HARD WIRED
Sample Nameplate (see your chassis nameplate)
MODEL NO 1
SERIAL NO *
FRIEDRICH AIR CONDITIONING CO.
SAN ANTONIO rTEXAS
VOLTS: 24,33,34
VOLTAGE RANGE: 255-197
REFRIG CHARGE: 70ZS. R22
DESIGN PRESSURE: 575 PSIG HS/150 PSIG LS
COOLING: BTU/HR 8
SEER: 10 COP: 16
HEAT PUMP BTUIRR: 14
TOTAL COOLING AMPS: 9
TOTAL ELEC. HEAT AMPS: 15
ELECTRIC HEAT WATTS: 18
FOR PERMANENTLY CONNECTED UNITS ON
COMP'. PLA 11 LRA 12
MOTOR: FLA 13 RP 19
HEATER AMPS: 17
MIN. CKT AMP ~0 US
OR HACR TYPE CIRCUIT BREAKER.
GENERAL UNIT INFORMATION:
MAX OUTLET AIR TEMPERATURE: 2OO'F
MAX EXTERNAL STATIC PRESSURE ELECTRIC
HEAT'..5 IN. WATER
"O" CLEARANCE TO COMBUSTIBLE MATERIAL
WARNING
ELECTRICAL SHOCK AND
MOVING PARTS HAZARD
CAN CAUSE INJURY OI
PUL
BEFORE
SERVICING.
LISTED
120524
HEATING AND
COOLING EQUIPMENT
APPLICABLE PATENTS:
US 6,065,296
NY MEA NO.: 295-00-E
USE ONE OF THE
FOLLOWING ITEMS
TO COMPLETE THE
ASSEMBLY
WALL PLENUM:
VPAWP1 -8
VPAWPI -14
OUTDOOR GRILLE
VPAL2
INDOOR GRILLE
VPRGI
VPRG2
VPRG5
USE ON SINGLE OUTLET CIRCUIT ONLY
Important: all 208/230v chassis must be hard wired withproperly sized breaker. See nameplate for specific chassis
electrical requirements. See page 8 - Figure 5for unitwiring and wall thermostat wiring. See page 8for wire size. Use
HACR type breakers to avoid nuisance trips. All field wiring mustbe done in accordance with nec and localcodes.