Page 2
MODELS QTXE110S • QTXE110S2
TYPICAL INSTALLATIONS
Housing mounted to
I-joists.
Housing mounted anywhere
between trusses using hanger
bars.
PLAN THE INSTALLATION
1. Choose the
installation
location.
The location of
your humidity
sensing fan is
very important.
Use the follow-
ing guidelines
for best opera-
tion:
Housing mounted anywhere be-
tween I-joists using hanger bars.
Housing mounted to joists.
Housing mounted anywhere be-
tween joists using hanger bars.
Housing mounted anywhere be-
tween trusses using hanger bars.
INSTALL HOUSING &
DUCT
1a. Mount
housing
to joist
or I-joist.
Use a pliers to
bend housing
TABS out to
90
0
. Hold hous-
ing in place so
that the hous-
ing tabs con-
tact the bottom
of the joist.
The housing
mounts with
four (4) screws
or nails. Screw
or nail housing
to joist through
lowest holes in
each mount-
ing flange,
then through
highest holes.
SPACER
(use for mounting to I-Joist)
TABS
I-JOIST
NOTE: Mounting to I-JOIST (shown) requires use of
SPACERS (included) between the highest hole of each
mounting flange and the I-joist.
OR
• Locateunitabove(GFCIprotectedcircuitrequired)or
within 5 feet of shower head.
• Locateunitawayfromheatingorcoolingsources
which can affect humidity levels.
• Donotlocatenearwindow.Unitmayrespondtothe
outdoor humidity level.
• Unitmustbeinstalledinceilingtoproperlysense
moisture.
• Locateunitonlyonflatceilingsupto12feethighfor
proper sensing.
• Theductingfromthisfantotheoutsideofthebuilding
has a strong effect on the air flow, noise and energy
use of the fan. Use the shortest, straightest duct rout-
ing possible for best performance, and avoid installing
the fan with smaller ducts than recommended. Insula-
tion around the ducts can reduce energy loss and
inhibit mold growth. Fans installed with existing ducts
may not achieve their rated airflow.
2. Plan the wiring.
• Plantosupplytheunitwithproperlinevoltageand
appropriate power cable. Power cable should be
routed to the switch box first and then to the unit
(See “CONNECT WIRING” on page 3).
• Donotoperatethisunitwithaspeedcontrol.
Damage to the sensor unit will result.
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
ROOF CAP*
(with built-in
damper)
FAN
HOUSING
POWER
CABLE*
6-IN. ROUND
DUCT*
6-IN.
ROUND
ELBOWS*
Seal gaps
around
Housing.
Seal duct
joints with
tape.
OR
Keep duct
runs short.
WALL CAP*