ADJUSTMENT OF THE OVEN BURNER MINIMUM
(LEFT and RIGHT OVEN)
This needs to be done only for the oven burner (the broil is a fixed capacity) by acting
on the thermostat in the following way:
– Turn on the burner by setting the thermostat knob on position 8.
– Remove the knob and unscrew the by-pass screw "G" (fig. 2.12) about three times by
passing a small flat screwdriver (Ø 3 mm blade, 100 mm length) through the panel
opening.
– Re-mount the knob and let the oven heat up for about 10 minutes, then bring the knob
to position 1 (minimum) to operate the thermostat by-pass.
After having removed the knob again and being very careful not to turn the tap rod,
slowly screw the by-pass screws “G” (fig. 2.12) until you obtain a flame of 3-4 mm in
height.
N.B. For LP/PROPANE gas the by-pass screw must be fixed thoroughly.
After regulation repeat the operations indicated in paragraph “2. PRESSURE
REGULATOR” at page 15 and 20
If the range has been disconnected and then connected again to the gas supply line
repeat the operations indicated in paragraph “5. LEAK TESTING” at page 20.
IMPORTANT:
After conversion to LP/PROPANE gas has been carried out afx near the data plate
the conversion label supplied and also afx a conversion label at page 3 of this
instruction manual.
After conversion back to the original gas (NATURAL GAS) has been carried out
remove, near the data plate and at page 3 of this instruction manual, the LP/
PROPANE conversion labels. Save the labels removed for future use.