Whirlpool WFG505M0MS 5.1 Cu. Ft. Stainless Steel Freestanding Gas Range With Edge-To-Edge Cooktop S

User Manual - Page 8

For WFG505M0MS.

PDF File Manual, 32 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
8
3. Determine and mark centerline of the cutout space. The
mounting can be installed on either the left side or right side
of the cutout. Position mounting bracket against the wall in
the cutout so that the V-notch of the bracket is 9
5
8
" (24.6 cm)
from centerline as shown.
A. 9
5
8
" (24.6 cm)
B. Bracket V-notch
4. Drill two 1/8" (3 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
Rear position
Front position
Diagonal (2 options)
Wall Mounting
5. Using the Phillips screwdriver, mount anti-tip bracket to
the wall or oor with the two #12 x 1
5
8
" (4.1 cm) screws
provided.
6. Move range close enough to opening to allow for nal
gas and electrical connections. Remove shipping base,
cardboard, or hardboard from under range.
7. Move range into its nal location, making sure rear leveling
leg slides into anti-tip bracket.
8. Move range forward onto shipping base, cardboard, or
hardboard to continue installing the range using the following
installation instructions.
Make Gas Connection
Typical exible connection
1. Apply pipe-joint compound made for use with Propane gas
to the smaller thread ends of the exible connector adapters
(see B and F in the following illustration).
2. Attach 1 adapter to the gas pressure regulator and the other
adapter to the gas shut-off valve. Tighten both adapters,
being certain not to move or turn the gas pressure regulator.
3. Use a 15/16" (2.4 cm) combination wrench and an adjustable
wrench to attach the exible connector to the adapters.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn when tightening
ttings.
A. Pressure regulator
connection tting
B. Use pipe-joint compound.
C. Adapter
D. Flexible connector
E. Adapter
F. Use pipe-joint compound.
G. Manual shut-off valve
H. 1/2" (1.3 cm) or 3/4" (1.9 cm)
gas pipe
Centerline
B
A
C
E
G
H
A
D
F
B
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Loading ...