Loading ...
Loading ...
Loading ...
Avoid Service Checklist
Beforecallingfor service,reviewthis list.It may save youtimeand expense.Thislist
includescommonoccurrencesthat are not the resultof defectiveworkman-shipor
materialsin thisappliance.
OCCURRENCE SOLUTION
Air conditioner wM not operate.
Airfrom unitdoea notfealcold
enough.
Wailplugdisconnected.Pushplugfirmlyintowalloutlet.
PlugCurrentDeviceTripped.Pressthe RESETbutton.
Housefuseblownor circuitbreakertripped.Replacefusewithtimedelaytypeor resetoimuitbreaker.
Con_'olisOFF. TurnControlON and settodesiredsetting.
Roomtemperaturebelow60°F (16°C).Coolingmaynotoccuruntilroomtemperaturerisesabove60°F (16°C).
Temperaturesensing elementtouchingcoldcoil,locatedbehindair tilter.Straightenaway fromceil.
Resetto a Lowertemperature.
Compressorshut-offby changingmodes.Waitapproximately3 minutesand listenfur compressorto res_ad
whensetin theCOOL mode.
Air conditioner cooling, but room is
too warm - iceforming on cooling
coil behinddecorative front.
Outdoortemperaturebelow80°F (18°C). Todefrost theceil, set FANONLY Mode.
Airfiltermaybe dirty.Cleanfilter.Referto Careand Cleaningsection. Todefrost,setto FANONLYMode.
Temperatureisse_ttooLowfornight-timecooling.Todefrosttheceil, set toFANONLY Mode.Then, setTem-
peraturetoa Highersetting.
Air conditioner cooling, but room is
too warm - NO Ice forming on
coonng coil behind decorative front.
Dirtyairtilter- air restricted.Cleanairfilter. Referto Careand Cleaningsection.
Temperatureisset tooHigh.Set temperaturetoa Lowersetting.
Air directionallouverspositionedimproperly.Positionlouversforbetterairdistribution.
Frontofunitisblockedbydrapes,blinds,furniture,etc. - restrictsairdistribution.Clearblockageinfrontofunit.
Doors,windows,registers,etc. open-coldairescapes.Closedoors,windows,registers,etc.
Unitrecentlyturnedoninhot room.Allowadditionaltimetoremove=storedheat"from walls,ceiling, floorand
furniture.
Air conditioner turns on end off
rapidly.
Dirtyairtilter- air restricted.Cleanair filter.
Outsidetemperatureextremelyhot. Set FANspeed to a fastersetdng to bringair past coolingceils more
frequently.
Noise when unit is cooling.
Air movementsound.Thisis normal.Iftoo loud,setto aslowerFANsetting.
Windowvibration-poorinstallation.Referto installationinstructionsor checkwithinstaller.
Water dripping iNSiDE when unit is Improperinstallation.Tiltair conditionerslightlyto the outsideto allowwater drainage.Refer to installation
cooling, instructions- checkwithinstaller.
Water dripping OUTSIDE when unit Unitremovinglargequantityofmoisture from humidroom.Thisisnormalduringexcessivelyhumiddays.
is cooling.
Remote Sensing Deactivating Remotecontrolnotlocatedwithinrange.Placeremotecontrolwithin20feet &180°, radiusofthefrontof the
Prematurely (Some Models). unit.
Room Too Cold.
Remotecontrolsignalobstructed.Removeobstruction.
Settemperature too low.Increaseset temperature.
Remote Sensingactivated(on somemodels)and remotecontrollocatedin Hot Spot- Relocateremote
controlor deactivateremotesensing.
if These Solutions Fag, Caii 1-800-444-4944 For Frigidaire Service.
12