Haier 1422442 FlexFit Series Triple Zone Mini Split System with 34000 BTU Cooling Capacity, 34600 BTU Heating Capacity, 4U36MS2VHB Outdoor Unit, 3x AB12SC2VHA Ceiling Cassette Indoor Unit and 3x PB700IB Panel in White

User Manual - Page 9

For 1422442.

PDF File Manual, 56 pages, Read Online | Download pdf file

1422442 photo
Loading ...
Loading ...
Loading ...
31-5000001 Rev. 6
9
ENGLISH
Outdoor Unit Clearances
Step 1 - Preparation
NOTE: If there is danger that the unit will fall or turn over,
fix the unit by inserting bolts, wire or other foundation
options.
NOTE: Place the unit on a level mounting base (or a plastic
pedestal) for proper drainage.
NOTE: Install the outdoor unit in a level position. Failure
to do so may result in water leakage or accumulation.
(3) Installation and maintenance space
Selection of installation location of outdoor
8
Select the Outdoor location:
Choose a level place solid enough to bear the weight and
vibration of the OD unit and where the operation noise will
not be amplified.
Choose a location where the hot air discharge and/or noise
will not create a nuisance for neighbors.
Ensure there is sufficient space to maneuver the OD unit
into place.
Ensure there is sufficient space and no obstructions for the
air inlet and outlet.
• I nstall the unit’s power/communication wiring at least
10 feet away from television and radio sets to prevent
interference.
Ensure any moisture sensitive items are kept away from the
condensate drain path of the OD unit.
• Choose a location not affected by heavy snowfall or wind.
• To prevent wind exposure, install a wind baffle.
INSTALLATION INSTRUCTIONS
Loading ...
Loading ...
Loading ...