B. Lock the casters-Be sure the system is on level ground to prevent un-intended movement of the
system. Move the lever on the casters to ON to secure the system.
C. Water and Moisture-The KBA & KBA Plus is not rated for outdoor use; avoid using the systems in
damp and wet areas or transporting them in uncovered vehicles.
D. Power-Each KBA or KBA Plus system must have its own dedicated power to operate. Extension
cords are allowed, but no longer than 25’.
VII / Maintenance
A. Pre Filter- KBA& KBAP systems come from the factory with a washable pre-filter installed on the
evaporator inlet to prevent dust and debris from entering the HEPA filter that is also pre-installed. You will
need to periodically clean the pre-filter based on your air quality, for optimum performance inspect/clean
this filter every 30 days, and more often if operated in poor air quality. Open the filter access door, below
the control by releasing the 2 slotted fasteners on the right side of the compartment. Remove the pre-filter
from the door frame and use a compressed gas in an approved area wearing the proper PPE to blow
through the filter to remove loose particles and then rinse the filter with clean water, allow complete drying
before re-installing. Failure to maintain the pre filter will cause restricted air flow and low overall unit
performance.
B. Filter Replacement:ULPA/HEPA filters 21”X13.5”X4”.
For optimum performance, inspect/replace HEPA filters every 90 days of operation.
Unplug your system - Remove any and all power sources from the unit.
Access the filters - Loosen the two screws on the filter access door until the door
Opens.
Remove the charcoal filter (optional) - Removethe charcoal filter by sliding the filter forward past the
frame and set aside. Replace if needed.
Remove the ULPA/HEPA filter Pull forward on the top of the filter until it stops, then pull forward on the
bottom of the filter until it stops, use this method alternating top to bottom until the filter clears the frame.
Do not jam the filter by pulling too hard.
Install the new ULPA/HEPA filter - Noting the correct air flow direction, push the
ULPA/HEPA filter into the housing.
Install theoptional charcoal filter - Push the top edge of the charcoal filter into the lip of the frame and then
repeat for the bottom. Close the front panel. Push the front panel closed and tighten the screws until
they are firmly secured.
UVC Bulb Replacement KBA Plus Only
Bulb - Max Voltage: 210 Volts | Max Wattage: 85 Watts. Call 1-800-KWIKOOL
(594-5665) for replacement UVC bulbs.
Bulb Replacement:
Unplug your system - Remove any and all power sources from your system.
Open the filter access door Loosen the 2 slotted fasteners on the filter panel until the door opens.
Remove the optional charcoal filter, if installed by pulling it forward from the frame. Remove the
ULPA/HEPA filter Pull forward on the top of the filter until it stops, then pull forward on the bottom of the
filter until it stops, use this method alternating top to bottom until the filter clears the frame. Do not jam the
filter by pulling too hard. Once removed, the return air compartment is revealed and the UV bulbs are
visible at the bottom of the compartment. For best results replace both UV bulbs at the same time to
ensure the most efficient operation of your KwiKool Bio Air PlusUnplug the UVC bulb - With one hand
holding the plug and the other holding thewhite end cap of the bulb in place, pull the two apart.Remove
the bulb from your system - Reach inside the unit and pull the bulb out ofits retaining clips from the middle
of the bulb. Properly dispose of the old UVC bulb.
Install the new bulb - Take the bulb in your hand, slide your hand with the bulb into