Battery Replacement:
Ensure test leads are disconnected from
circuit or components.
Remove test leads from input jacks
on meter.
Remove the two screws from the
battery cap.
Remove the battery cap.
Replace batteries with two
“AAA” batteries.
Assemble the battery cap
to the meter and re-tighten
the screws.
Maintenance:
Switch off and disconnect the meter completely before carrying out any maintenance.
Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
Keep away from liquids and ensure the meter is completely dry before use.
Service and Replacement Parts:
This unit has no user-serviceable parts.
For replacement parts or to inquire about service information contact IDEAL
INDUSTRIES, INC. at 1-877-201-9005 or visit our website www.idealindustries.com.
Specifications:
Display: 3-3/4 digit LCD with 4000 counts
Polarity: Automatic, positive implied, negative (-) polarity indication.
Overrange: “OL” indication is displayed.
Measure Rate: Samples 2 times per second, nominal.
Auto Power Off: Approximately after 10 minutes of non-use.
Battery Life: 400 hours continuous with Alkaline (61-744)
250 hours continuous with Alkaline (61-746)
Page 9
Low Battery Indication: The “ “ is displayed when battery voltage drops below
operating level.
Power Supply: (2) 1.5V “AAA” batteries (NEDA R03).
Includes an isolated battery compartment.
Accuracy: Stated accuracy at 23°C ±5°C, <75% R.H.
Temperature 0.1 x (specified accuracy) per °C,
Coefficient: (0°C to 18°C, 28°C to 50°C).
Altitude: 6561.7 ft. (2000m)
Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H.
Storage Environment: -4°F to 140°F (-20°C to 60°C) at < 80% R.H.
Jaw Opening: Accepts a 1.50” (38mm) conductor
Dimensions: 8.0”H x 2.6”W x 1.5”D (203mm H x65mm W x37mm D)
Weight: 7.1 oz (200g) including batteries
Accessories included: Carrying Case, Test Leads, (2) 1.5V “AAA” batteries,
operating instructions.
Safety: Complies with UL/IEC/EN: 61010-1, 61010-2-032,
61010-031 specifications, Cat III-600V.
Double Insulation
Instrument has been evaluated and complies with insulation category III (overvoltage
category III). Pollution degree 2 in accordance with IEC-644. Indoor use.
Ranges & Accuracies:
AC Converter:
61-744 model is averaging sensing, rms calibrated
61-746 model is true rms sensing.
Accuracy:
Accuracy is specified as +/-(a percentage of the reading + a fixed amount) at
23°C±5°C (73.4°F ± 9°F), less than 75% relative humidity.