@0GAS CONVERSION
Injectors table
BURNERS
NOMINAL
POWER
REDUCED
POWER
LP/PROPANE
11” (279.4mm)
W.C.P.
NATURAL GAS
4” (101.6mm)
W.C.P.
BTU/HR BTU/HR
Ø INJECTOR
[1/100 MM]
Ø INJECTOR
[1/100 MM]
Semirapid (SR)
7600
(LP/Propane Gas) 1800 78 –
8000
(Natural Gas) 1800 – 136
Triple Ring
12000
(LP/Propane Gas) 6300 97 –
14000
(Natural Gas) 6300 – 180
Dual (D)
Inner crown 2800
1
1100
1
47
3
80
3
Full burner 18000
2
6500
2
79 (x2)
4
135 (x2)
4
GAS GAS MODELS ONLY
Oven burner 17000 3200 120 208
Broil burner 13000 – 105 184
1 Power calculated only with inner crown operating
2 Power calculated with inner and outer crown operating
3 Inner crown injector
4 Outer crown injector
Replacing the cooktop burner injectors
●
Remove the pan supports, the burner caps and the flame spreaders.
●
Using a wrench substitute the nozzle injectors with those most
suitable for the kind of gas for which it is to be used.
●
Refit the flame spreaders, the burner caps and the pan supports.
The burners are designed so that no regulation of the primary air is
required.
Semi-rapid burner Dual burner
Inner crown injector
Inner crown injector
Inner crown injector
Outer crown injector