Operating Your Unit
Auto Locking Control Panel
• Press button for 2 seconds to unlock the panel. With no operation for 20
seconds, the panel will be locked automatically. Under locking status, the
temperature can’t be adjusted, while and buttons can work normally.
• Short press to turn it on or off. Long press the button to switch between
Fahrenheit and Celsius display
• With all the buttons of no operation for 10 minutes, the lamp will turn off
automatically.
• Press the button and to adjust the temperature in 2°F / 1°C
increments. Temperature ranges from minimum 41°F / 5°C to maximum
64°F / 18°C.
Forced Defrosting Function: when the compressor works for 8 hours, the
compressor will stop working for 45 minutes
Memory function: the control board is re-energized after each power-off. The
temperature setting and Fahrenheit/Celsius state will be the same as before
the last power-off regardless of the length of power-off time.
Error Code
EE
"EE" is displayed when the temperature probe is short-circuited
or disconnected, flashes, and cooling is stopped
"LL" is displayed when the temperature measured by the temperature
probe is lower than 32°F, flashing, and the cooling is stopped
"HH" is displayed when the temperature measured by the temperature
probe is higher than 99°F, flashing, and cooling is stopped
LL
HH
Cause