SECTION 2: IGNITION CONTINUED
If there are no flames present,
as demonstrated in the image
to the left, the appliance is likely
not burning. If this is the case,
IMMEDIATELY turn the valve
to the “off” position if it is not
already and repeat the ignition
procedure as outlined in Section 2.
Upon igniting the appliance,
visually verify that the burner is
indeed burning as demonstrated
in the image to the left. The
presence of flames will confirm
that the burner is burning.
Periodically check that the burner
flame is present during operation
by visually inspecting the burner to ensure the presence of flames.
STEP 6
Using a lighter or match, ignite
lighter and hold flame slightly
above the burner, then open the
valve on the appliance slowly
by turning (counter-clockwise)
until the unit ignites.
STEP 7
Once the unit is burning normally
set the dial to desired flame
height.
WARNING: Ensure that no parts of your body, clothing, or any other combustible material are above the burner before, during
and after ignition.
SECTION 3: PERIODIC INSPECTION OF BURNER FLAMES
STEP 8
GOT A LOW FLAME?: If your firebowl experiences low flame, or flame height does not appear to be normally adjusted by the
gas knob, it is likely that the CSA excess flow safety device has been tripped in the hose regulator.
CORRECTIVE ACTION: Close propane cylinder valve. Open and then close Firebowl gas knob valve to release pressure.
Disconnect and reconnect the propane cylinder valve connection. Slowly open propane cylinder valve. Perform Leak Test and
follow Ignition sequence.
WHAT IS AN EXCESS FLOW SAFETY VALVE? (EFV)
The EFV is a safety mechanism contained within every propane gas
regulator. The purpose of the EFV is to restrict the gas supply if too
much gas is flowing too quickly through the gas hose. For example,
this could happen if the gas hose was severed.
It is normal that your Fire Bowl EFV trips if you open the propane tank
valve too quickly or if you leave the Fire Bowl gas knob open before
lighting, or both.
EXCESS FLOW
VALVE
GAS REGULATOR
GAS
HOSE