4. Installation
2. Eaves Installation
After ensuring sucient clearance exists for the mounting ange and ducting (gure 1), cut a circular hole
165mm Ø, maintaining adequate clearances. The eave sheeting must be reinforced.
Pre-drill mounting ange recess (gure 4).
If access to the eave space is restricted, before xing the mounting ange to the eave, preassemble the
mounting ange, PVC pipe, bell-mouth adaptor and exi-duct, then feed up into roof space. Remember to run
power cord through the assembly and out the slotted PVC pipe wall (gure 4).
Fit the fan module to mounting ange by placing in position, rotating clockwise to engage bayonet ngers then
secure by screwing in locking screw (while holding fan module rmly in the fully clockwise position).
Ensure that one of the three
bayonet ngers is accessible for
securing locking screw
Bell-mouth Adaptor
Roof Cladding
Locking Screw
Pre-drill mounting
ange recess and secure
to reinforced eaves
sheet using #8 self
tapping screws
Wall
Eaves
Top Plate
150mm Ducting
Roof Frame/Truss
Figure 4